Desa and EFS26NR For Built-In Installation, Extension Cord, Removing Upper Louver Assembly

Page 14

14

INSTALLATION

Installing Blower Accessory GA3450T in Remote-Ready Models (Cont.) Installing Blower Accessory GA3450T in Thermostat-Controlled Models

INSTALLATION

Continued

For Built-In Installation

WARNING: A licensed electrician must connect the wiring harness to electrical supply following all local codes.Electricianmustprovideaclampontheboxcover to secure the wiring. Wiring should be routed through the bushing in the hole on the outer casing of fireplace.

1.Install a snap bushing found in hardware kit into one of the holes on rear of valve cover shield. The other hole is for a strain relief clamp (not supplied) to secure incoming electrical supply.

2.Follow steps 2 through 6 in Installing Blower Accessory, page 13.

3.A licensed electrician must follow the wiring diagram to con- nect incoming electrical supply to fan kit wiring harness (see Figure 19).

4.Plug power cord to the outlet receptacle (not provided) as shown in Figure 20. w in power cord and tie it up with the plastic wire strap (see Figure 20). Set the cable bundle between the burner bracket and outer casing, away from the burner.

 

Fan Switch

 

 

 

 

 

 

 

(Auto/Off/On)

 

 

 

 

 

 

 

 

1 Auto

 

 

 

 

 

 

 

Off

2

 

 

 

 

 

 

 

 

 

 

 

3

Blue

 

Thermostat

 

 

 

On

 

 

 

Switch

 

 

 

 

 

 

(N.O.)

110/115

 

 

Red

 

 

 

 

Blue

V.A.C.

 

 

 

 

Blower

 

Black

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

Red

 

 

White

 

 

 

 

 

 

White

 

 

Green

 

 

 

 

 

 

Green

Figure 19 - Wiring Diagram For Blower Accessory Built-In Installation

5.Test to make sure the blower is working properly.

6.Reinstall upper louver assembly (see Figure 15, page 12) and close lower louver.

Extension Cord

Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An undersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

INSTALLING OPTIONAL BLOWER ACCESSORY GA3450T IN THERMOSTAT- CONTROLLED MODELS

Removing Upper Louver Assembly

To install the blower accessory, you must first remove the upper louver assembly.

1.Remove 4 screws from upper louver assembly (see Figure 21). Save these screws.

2.Pull upper louver assembly straight out from the cabinet. Be care- ful not to scratch the paint. Set louver assembly and screws aside.

Blower Bracket

Mounting Holes

Blower Bracket

Assembly

Screw

SwitchPower Cord

Switch

Plate

Blue

Red

Black

Wire Harness

Plastic Wire Strap

Lower Louver Door

Wire Harness

Outlet Receptacle (not included)

Clamp Connector (not included)

 

Upper Louver

Brass Screws

Assembly

 

Figure 21 - Removing Upper Louver Assembly

Figure 20 - Installing Blower Bracket Assembly

For..com

107032-01H

Image 14
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented VENT-FREE GAS Compact Classic Hearth Fireplace Table of Contents Safety InformationProduct Identification Vent-Free Compact Classic Hearth FireplaceLocal Codes Optional Remote Control AccessoriesProduct Features UnpackingAssembly Assembling FireplaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion and VentilationProviding Adequate Ventilation Ventilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsFireplace Clearances Installation ItemsCheck GAS Type BUILT-IN Fireplace Installation Rough Opening for Installing in WallOptional Mantel Installation Mantel Clearances for Built-In InstallationRemoving Upper Louver Assembly and Branch Support Assembling Brass Trim Brass trim shipped with mantelInstalling Blower Accessory Power Cord SnapExtension Cord For Built-In InstallationRemoving Upper Louver Assembly Installing Blower Assembly Removing Valve Cover ShieldValve Cover Shield Switch PlateScrew Connecting to GAS Supply Attaching Wood Base to Solid FloorConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing gas Supply Piping system Checking GAS ConnectionsInstalling Receiver Optional Wireless HAND-HELD Remote Control AccessoriesPressure Testing Fireplace Gas Connections Installing 9-Volt Battery in Hand-Held Remote Control Unit Optional Wall Mounted Thermostat GWMT1Optional Wall Switch GWMS2 Remote-Ready Models Only Installing LOG SET and ScreenOperating Fireplace Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting Thermostat Control OperationPropane/LPGasPilot Optional HAND-HELD Remote Operation Manual ModeAuto Thermostatic Mode Thermostat Series Model GhrctbGWMT1 Wall Mounted Thermostat Optional GWMS2 Wall Mounted Switch Optional Operating BlowerSafety Features Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceWiring Diagram LOG SETTroubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Service Hints SpecificationsReplacement Parts Technical ServiceIllustrated Parts Breakdown THERMOSTAT-CONTROLLED Models VMH10TPB, VMH10TNBParts List THERMOSTAT-CONTROLLED Models22 36 REMOTE-READY Models Accessories WALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT GCKWALL-MOUNT Thermostat Switch GWMT1 Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbFor . .com Owners Registration Form Postage Required 107032-01H Warranty Information

EFS10TP, EFS10TN, and EFS26NR specifications

Desa is a recognized leader in the innovation and manufacture of advanced heating solutions designed to deliver optimal performance and efficiency. Among their most notable offerings are the EFS26NR, EFS10TP, and EFS10TN models, each engineered with unique features and technologies to meet diverse heating needs.

The EFS26NR is a notable model known for its large heating capacity and effectiveness in maintaining consistent warmth in larger spaces. With a robust output, this unit can efficiently heat areas up to 1,800 square feet, making it suitable for homes or commercial settings. One of the primary characteristics of the EFS26NR is its advanced heating technology, which includes a high-efficiency burner that maximizes fuel usage, reducing operational costs. Additionally, it features a built-in thermostat, providing automated temperature adjustments for enhanced comfort.

On the other hand, the EFS10TP is designed for versatility and practicality. This model is ideal for smaller rooms or as a supplementary heating option. The EFS10TP offers users the convenience of a portable heater equipped with wheels, allowing for easy mobility. This model is equipped with user-friendly controls and a safety shut-off feature, ensuring peace of mind while in use. The EFS10TP utilizes a compact design without sacrificing performance, allowing it to fit seamlessly into various settings.

Similar in size, the EFS10TN focuses on energy efficiency as its main selling point. This model uses a unique infrared heating technology that allows for more direct heating of objects and people rather than warming the air, resulting in lower energy consumption. The EFS10TN is perfect for those looking to reduce their carbon footprint while still achieving a warm, inviting environment. Enhanced safety features such as tip-over protection and overheat shut-off further ensure its suitability for use in homes with children or pets.

Overall, the Desa heating solutions—EFS26NR, EFS10TP, and EFS10TN—each provide distinct advantages tailored to specific heating requirements. With a commitment to innovation, safety, and efficiency, these models are exemplary choices for those seeking dependable and effective heating options. Whether for large areas or cozy spaces, Desa ensures that there is a suitable solution for every heating need.