Desa EFS10TP, EFS10TN, and EFS26NR Check GAS Type, Installation Items, Fireplace Clearances

Page 9

INSTALLATION

Check Gas Type

Installation Items

Fireplace Clearances

9

INSTALLATION

Continued

Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fireplace Installation, page 10).

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

INSTALLATION ITEMS

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer, for propane/LP units only)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection*

ground joint union

sediment trap

tee joint

pipe wrench

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, pages 38 and 39.

Note: If desired, purchase a four-sided brass trim kit for built-in installations. See Accessories, pages 38 and 39.

FIREPLACE CLEARANCES

WARNING: Maintain the minimum clearances shown in Figure 7. If you can, provide greater clear- ances from floor, ceiling, and joining wall.

NOTICE: If you install the fireplace in a bedroom (Thermostat-Controlled Models only), some building codes require that the fireplace/mantel system be secured to (or within) a wall. You can position fire- place in an optional cabinet or corner mantel. You can also recess fireplace into the wall.

If your fireplace is to be used with an optional mantel, the installation instructions included with your mantel shows an CSA approved method of attaching the fireplace/mantel system to a wall. IMPORTANT: Only use optional cabinet or corner mantels specified in this manual. Purchase the optional mantel from your dealer (see Accessories, pages 38 and 39).

If your fireplace is to be recessed into the wall, see Built-In Fireplace Installation on page 10 to secure your fireplace into the wall.

CAUTION: If you install the fireplace in a home garage

fireplace pilot and burner must be at least 18 inches above floor.

locate fireplace where moving vehicle will not hit it.

For convenience and efficiency, install fireplace

where there is easy access for operation, inspection, and service

in coldest part of room

An optional blower kit is available from your dealer. See Accesso- ries, pages 38 and 39. If planning to use blower, follow instructions provided with blower for power source.

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling

A.Clearances from the side of the fireplace cabinet to any com- bustible material and wall should follow diagram in Figure 7.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 7).

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 36 inches.

C.For mantel clearances, see Figure 11 on page 11.

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Bottom

 

Right Sides

and Rear

36"

6"

0"

 

Example

 

 

 

*

*Minimum 16 inches from Side Wall

Figure 7 - Minimum Clearance for Combustible to Wall

For morevisit www..com

107032-01H

Image 9
Contents OWNER’S Operation and Installation Manual Unvented VENT-FREE GAS Compact Classic Hearth FireplaceWhat to do if YOU Smell GAS Safety Information Table of ContentsVent-Free Compact Classic Hearth Fireplace Product IdentificationProduct Features Optional Remote Control AccessoriesLocal Codes UnpackingAssembling Fireplace AssemblyAIR for Combustion and Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationInstallation Items Check GAS TypeFireplace Clearances Rough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationAssembling Brass Trim Brass trim shipped with mantel Removing Upper Louver Assembly and Branch SupportPower Cord Snap Installing Blower AccessoryFor Built-In Installation Removing Upper Louver AssemblyExtension Cord Removing Valve Cover Shield Installing Blower AssemblyValve Cover Shield Switch PlateScrew Attaching Wood Base to Solid Floor Connecting to GAS SupplyInstallation Items Needed Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemOptional Wireless HAND-HELD Remote Control Accessories Pressure Testing Fireplace Gas ConnectionsInstalling Receiver Optional Wall Mounted Thermostat GWMT1 Installing 9-Volt Battery in Hand-Held Remote Control UnitInstalling LOG SET and Screen Optional Wall Switch GWMS2 Remote-Ready Models OnlyLighting Instructions Operating FireplaceREMOTE-READY Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationPropane/LPGasPilot Auto Thermostatic Mode Manual ModeOptional HAND-HELD Remote Operation Thermostat Series Model GhrctbGWMS2 Wall Mounted Switch Optional Operating Blower Safety FeaturesGWMT1 Wall Mounted Thermostat Optional Inspecting Burners Pilot Flame PatternBurner Flame Pattern Wiring Diagram Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole LOG SETObserved Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement Replacement Parts SpecificationsService Hints Technical ServiceTHERMOSTAT-CONTROLLED Models VMH10TPB, VMH10TNB Illustrated Parts BreakdownTHERMOSTAT-CONTROLLED Models Parts List22 36 REMOTE-READY Models Accessories WALL-MOUNT Thermostat Switch GWMT1 Cleaning KIT GCKWALL-MOUNT ON/OFF Switch GWMS2 Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbFor . .com Owners Registration Form Postage Required 107032-01H Warranty Information

EFS10TP, EFS10TN, and EFS26NR specifications

Desa is a recognized leader in the innovation and manufacture of advanced heating solutions designed to deliver optimal performance and efficiency. Among their most notable offerings are the EFS26NR, EFS10TP, and EFS10TN models, each engineered with unique features and technologies to meet diverse heating needs.

The EFS26NR is a notable model known for its large heating capacity and effectiveness in maintaining consistent warmth in larger spaces. With a robust output, this unit can efficiently heat areas up to 1,800 square feet, making it suitable for homes or commercial settings. One of the primary characteristics of the EFS26NR is its advanced heating technology, which includes a high-efficiency burner that maximizes fuel usage, reducing operational costs. Additionally, it features a built-in thermostat, providing automated temperature adjustments for enhanced comfort.

On the other hand, the EFS10TP is designed for versatility and practicality. This model is ideal for smaller rooms or as a supplementary heating option. The EFS10TP offers users the convenience of a portable heater equipped with wheels, allowing for easy mobility. This model is equipped with user-friendly controls and a safety shut-off feature, ensuring peace of mind while in use. The EFS10TP utilizes a compact design without sacrificing performance, allowing it to fit seamlessly into various settings.

Similar in size, the EFS10TN focuses on energy efficiency as its main selling point. This model uses a unique infrared heating technology that allows for more direct heating of objects and people rather than warming the air, resulting in lower energy consumption. The EFS10TN is perfect for those looking to reduce their carbon footprint while still achieving a warm, inviting environment. Enhanced safety features such as tip-over protection and overheat shut-off further ensure its suitability for use in homes with children or pets.

Overall, the Desa heating solutions—EFS26NR, EFS10TP, and EFS10TN—each provide distinct advantages tailored to specific heating requirements. With a commitment to innovation, safety, and efficiency, these models are exemplary choices for those seeking dependable and effective heating options. Whether for large areas or cozy spaces, Desa ensures that there is a suitable solution for every heating need.