NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell.Thiswillonlylastafewhours.

1.STOP! Read the safety information on page 15.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation, page 15. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

C-clockwiseto the PILOT position.

Press in control knob for five (5) sec- onds (see Figure 28).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press- ing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas sup- plier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.This heater has a safety inter- lock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Ignitor Button

Control Knob

Figure 28 - Control Knob and Ignitor Button

Ignitor Electrode

Pilot Burner

Thermocouple

Figure 29 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise Clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT

CONTROL OPERATION

The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the Hi setting with the control knob will cause the burner to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, column 1.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instruc- tions, column 1.

For more information, visit www.desatech.com

16

107187

Image 16
Contents VENT-FREE PROPANE/LP GAS BAY Front Fireplace What to do if YOU Smell GASSafety Information VENT-FREE PROPANE/LP BAY Front FireplaceProduct Features Safety PilotLocal Codes Unpacking Product IdentificationAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Installation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Installation ItemsLocating Fireplace BUILT-IN Fireplace Installation DepthOptional Mantel Installation Mantel Clearances for Built-In InstallationRemoving Brick Liner Retainer Assembling Brass TrimInstalling Blower Assembly GA3450T AttachingBrassTrimtoFireplaceFor Built-In Installation Installing Switch Plate to Blower Control ShieldConnecting to GAS Supply External Regulator with Vent Pointing DownConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Installing LogsOperating Fireplace Manual Lighting Procedure Lighting InstructionsTo Turn OFF GAS To Appliance Thermostat Control OperationCleaning and Maintenance Inspecting BurnersTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Specifications Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown CF26PTParts List KEY Part Number Description QTY20-1 11-1 20-2 20-3 11-2 KEY CF26PT Description QTY Accessories Cleaning KIT CCKCabinet Mantel with Full Hearth Base Brass Accent Trim GA6095Owners Registration Form Postage Required Parts Centrals Warranty Information

CF26PT specifications

Desa CF26PT is a modern and efficient heating solution designed for residential and commercial spaces, providing comfort and convenience in various environments. This appliance stands out with its remarkable features that cater to diverse user needs.

One of the main features of the Desa CF26PT is its powerful heating capacity. With an output of up to 26,000 BTUs, it is capable of warming large areas quickly and effectively. This makes it an ideal choice for homes with open floor plans or larger spaces that require consistent warmth during colder months.

The technology integrated into the Desa CF26PT is another defining characteristic. The unit employs advanced heating technology, ensuring that it operates efficiently and reliably. This not only maximizes performance but also minimizes energy consumption, making it a cost-effective option for consumers. The inclusion of a multi-directional vent ensures that heat is distributed evenly throughout the space, eliminating cold spots and providing a comfortable environment.

In terms of design, the Desa CF26PT is compact and versatile, allowing it to fit seamlessly into various room styles. Its aesthetic appeal ensures that it complements existing décor while offering practical functionality. The unit is also designed for easy installation, with straightforward guidelines that allow users to set it up quickly without needing professional assistance.

Safety features are paramount in the design of the Desa CF26PT. It comes equipped with an automatic shut-off feature that activates in the event of overheating, ensuring peace of mind for users. Additionally, the unit incorporates a sturdy construction, making it durable and capable of withstanding the rigors of daily use.

User-friendly controls are another highlight of the Desa CF26PT. The intuitive interface allows users to adjust settings easily, ensuring personalized comfort. Whether it's choosing the desired temperature or setting up a timer, the functionality enhances the user experience, making it accessible for individuals of all ages.

In summary, the Desa CF26PT stands out as a reliable heating solution, offering power, efficiency, and safety in a stylish, compact design. Its advanced technology, user-friendly operation, and robust safety features make it a prominent choice for those seeking effective heating solutions in their spaces.