Desa CF26PT installation manual Troubleshooting, Observed Problem Possible Cause Remedy

Page 18

CF26PT

VENT-FREE PROPANE/LP BAY FRONT FIREPLACE

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no

1.

Ignitor electrode not connected to igni-

1.

Reconnect ignitor cable

spark at ODS/pilot

 

tor cable

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched by any

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor to base

 

 

 

 

panel of log set. Nut is located behind

 

 

 

 

base panel.

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode broken

6.

Replace piezo ignitor

 

7.

Ignitor electrode positioned wrong

7.

Replace piezo ignitor

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

spark at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is re-

 

 

 

 

moved

 

5.

Depleted gas supply

5.

Contact local propane/LP gas company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 17) or replace ODS/

 

 

 

 

pilot assembly

 

7.

Gas regulator setting is not correct

7.

Replace gas control

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

knob pressed in 30 seconds

 

3.

Equipment shutoff valve not fully open

3.

Fully open equipment shutoff valve

 

4.

Pilot flame not touching thermocouple,

4.

A) Contact local propane/LP gas com-

 

 

which allows thermocouple to cool,

 

pany

 

 

causing pilot flame to go out. This prob-

 

 

 

 

lem could be caused by one or both of

 

B) Clean ODS/pilot (see Cleaning and

 

 

the following:

 

Maintenance, page 17) or replace ODS/

 

 

A) Low gas pressure

 

pilot assembly

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten 1/4

 

 

trol valve

 

turn more

 

6.

Thermocouple damaged

6.

Replace thermocouple

 

7.

Control valve damaged

7.

Replace control valve

www.desatech.com

For more information, visit www.desatech.com

18

107187

Image 18
Contents VENT-FREE PROPANE/LP GAS BAY Front Fireplace What to do if YOU Smell GASSafety Information VENT-FREE PROPANE/LP BAY Front FireplaceLocal Codes Product FeaturesSafety Pilot Unpacking Product IdentificationUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsInstallation Items Check GAS TypeLocating Fireplace BUILT-IN Fireplace Installation DepthRemoving Brick Liner Retainer Optional Mantel InstallationMantel Clearances for Built-In Installation Assembling Brass TrimInstalling Blower Assembly GA3450T AttachingBrassTrimtoFireplaceFor Built-In Installation Installing Switch Plate to Blower Control ShieldConnecting to GAS Supply External Regulator with Vent Pointing DownConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Logs For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Thermostat Control OperationCleaning and Maintenance Inspecting BurnersTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Technical Service SpecificationsService Hints Replacement PartsIllustrated Parts Breakdown CF26PTParts List KEY Part Number Description QTY20-1 11-1 20-2 20-3 11-2 KEY CF26PT Description QTY Cabinet Mantel with Full Hearth Base AccessoriesCleaning KIT CCK Brass Accent Trim GA6095Owners Registration Form Postage Required Parts Centrals Warranty Information

CF26PT specifications

Desa CF26PT is a modern and efficient heating solution designed for residential and commercial spaces, providing comfort and convenience in various environments. This appliance stands out with its remarkable features that cater to diverse user needs.

One of the main features of the Desa CF26PT is its powerful heating capacity. With an output of up to 26,000 BTUs, it is capable of warming large areas quickly and effectively. This makes it an ideal choice for homes with open floor plans or larger spaces that require consistent warmth during colder months.

The technology integrated into the Desa CF26PT is another defining characteristic. The unit employs advanced heating technology, ensuring that it operates efficiently and reliably. This not only maximizes performance but also minimizes energy consumption, making it a cost-effective option for consumers. The inclusion of a multi-directional vent ensures that heat is distributed evenly throughout the space, eliminating cold spots and providing a comfortable environment.

In terms of design, the Desa CF26PT is compact and versatile, allowing it to fit seamlessly into various room styles. Its aesthetic appeal ensures that it complements existing décor while offering practical functionality. The unit is also designed for easy installation, with straightforward guidelines that allow users to set it up quickly without needing professional assistance.

Safety features are paramount in the design of the Desa CF26PT. It comes equipped with an automatic shut-off feature that activates in the event of overheating, ensuring peace of mind for users. Additionally, the unit incorporates a sturdy construction, making it durable and capable of withstanding the rigors of daily use.

User-friendly controls are another highlight of the Desa CF26PT. The intuitive interface allows users to adjust settings easily, ensuring personalized comfort. Whether it's choosing the desired temperature or setting up a timer, the functionality enhances the user experience, making it accessible for individuals of all ages.

In summary, the Desa CF26PT stands out as a reliable heating solution, offering power, efficiency, and safety in a stylish, compact design. Its advanced technology, user-friendly operation, and robust safety features make it a prominent choice for those seeking effective heating solutions in their spaces.