Desa EVGL850N installation manual Gas leak. See Warning statement at

Page 16

® EVGL850N

VENTED TYPE DECORATIVE APPLIANCE

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most fireplaces. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Fireplace burning vapors from paint, hair

 

 

spray, glues, etc. (See IMPORTANT

 

 

statement above)

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Ventilate room. Stop using odor caus- ing products while fireplace is running

2.Locate and correct all leaks (see Gas Line Hook-Up, page 9)

 

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Gas

Gas odor even when control knob is in OFF

 

top of page

 

Line Hook-Up, page 9)

position

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

1. Foreign matter between control valve

Gas odor during combustionand burner

2. Gas leak. See Warning statement at top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Gas Line Hook-Up, page 9)

 

1.

Improper log placement

1.

Properly locate logs (see Log & Ember

Dark residue on logs or inside of fireplace

2.

Air holes at burner inlet blocked

 

Placement, page 10)

 

 

 

2.

Clean out air holes at burner inlets. Pe-

 

3.

Burner flame holes blocked

 

riodically repeat as needed

 

 

 

3.

Remove blockage or replace burner

www.desatech.com

16

107050

Image 16
Contents EVGL850N Natural Electronic Ignition For Your SafetyWhat to do if YOU Smell GAS Vented Type Decorative Appliance Introduction Before YOU BeginSelecting Location PRE-INSTALLATION PreparationClearances Mantel Clearances and Wall Details FramingVenting Installation Typical B-Vent ConfigurationChecking for Proper Venting Min Roof PitchInstallation Wall Switch Installation EVGL850NGAS Line HOOK-UP OvertightenLOG & Ember Placement GAS Burner Supply HOOK-UPCombustion AIR KIT Model Akgl Optional Glass Door Removal and ReplacementAppliance Enclosure For Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceBurner Flame Adjustment Pilot Assembly AdjustmentOperating Guidelines and Maintenance Instructions Technical Service Service HintsWiring Diagram Troubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at Accessories Replacement Parts Parts Under WarrantyReceiver and HAND-HELD Remote Control KIT 00710 WRC Parts not Under WarrantyPilot Assembly Replacement PartsGAS Control Valve 107050 Warranty Information