Desa EVGL850N installation manual Introduction, Before YOU Begin

Page 3

OWNER’S MANUAL

INTRODUCTION

Model EVGL850N is a radiant heat decora- tive gas appliance that use an electronic gas control valve with electronic ignition sys- tem. A 5” B-Type venting system and a listed type vent cap are not supplied but are required for proper operation. See venting instructions on pages 6 and 7.

WARNING: This gas appli- ance must not be connected to a chimney flue servicing a solid fuel burning appliance.

Model EVGL850N uses NATURAL GAS ONLY.

If you have any doubts as to which gas your particular unit is approved and tested for use with, please check the rating plate located behind the control access door (Figure 1, page 2).

BEFORE YOU BEGIN

Before beginning the installation of your appliance, read these instructions through completely.

This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANS/ NFPA 70 or the Canadian Electrical Code, CSA C22.1.

The installation must conform with local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANS Z223.1 or with the current CAN/CGA B149 Installation Codes.

This appliance complies with ANS Z21.50- 1998 and CSA 2.22-M98 as Vented Gas Fireplaces and is listed and tested by the Canadian Standards Association to the above test standards.

WARNING: Installation of this appliance must be done by a quali- fied service person well trained in the installation of such appli- ances. You will also need a build- ing permit from your local Build- ing and Safety Commissioner before installing this appliance; otherwise your insurance co. may not cover this appliance.

This appliance is not intended to be used as a primary source of heat.

CAUTION: Do not connect appliance before pressure test- ing gas piping. Damage to gas valve may result and an unsafe condition may be caused.

The appliance and it’s individual equipment shutoff valve must be disconnected from the gas supply piping system during any pres- sure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its indi- vidual equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

For the purpose of input adjustment two pressure taps (for IN and OUT pressures) are provided on the gas control valve for test gauge connections to the appliance.

This DESA appliance and its approved com- ponents are safe when installed according to this installation manual and are operated as recommended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY CAUSE A FIRE

HAZARD!

The DESA warranty will be voided by, and DESA disclaims any responsibility for the following actions :

A)Modification of the appliance or any of the components.

B)Use of any component part not ap- proved by DESA in combination with this appliance.

C)Installation and/or operation in a man- ner other than instructed in this manual.

D)The burning of anything other than the type of gas approved for use in this gas appliance.

GAS RATING

Type of Gas

Natural

 

 

Max. Input Rating:

21,000 Btu/hr

 

 

Manifold Pressure:

3.5 in. WC (.87 kPa)

 

 

Minimum Supply Pressure:

4.5 in. WC (1.12 kPa)

 

 

Maximum Supply Pressure:

10.5 in. WC (2.66 kPa)

 

 

Orifice Size:

# 45

 

 

107050

3

Image 3
Contents For Your Safety EVGL850N Natural Electronic IgnitionWhat to do if YOU Smell GAS Vented Type Decorative Appliance Before YOU Begin IntroductionPRE-INSTALLATION Preparation Selecting LocationClearances Framing Mantel Clearances and Wall DetailsTypical B-Vent Configuration Venting InstallationMin Roof Pitch Checking for Proper VentingWall Switch Installation EVGL850N InstallationOvertighten GAS Line HOOK-UPGAS Burner Supply HOOK-UP LOG & Ember PlacementGlass Door Removal and Replacement Combustion AIR KIT Model Akgl OptionalAppliance Enclosure To Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsPilot Assembly Adjustment Burner Flame AdjustmentOperating Guidelines and Maintenance Instructions Service Hints Technical ServiceWiring Diagram Observed Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at Parts not Under Warranty Accessories Replacement PartsParts Under Warranty Receiver and HAND-HELD Remote Control KIT 00710 WRCReplacement Parts Pilot AssemblyGAS Control Valve 107050 Warranty Information