Desa EVGL850N installation manual Mantel Clearances and Wall Details, Framing

Page 5

OWNER’S MANUAL

MANTEL CLEARANCES AND WALL DETAILS

A combustible mantel shelf maybe installed a maximum 9" (229mm) from the wall and musthaveaminimumdistanceof18" (457mm) above the fireplace opening. Figures 5 and 6 show the minimum allowable distances from various combustible mantle components in relation to the fireplace opening.

FRAMING

1.

Frame appliance enclosure as illus-

 

trated in Figures 7 and 8.

 

Note: If a wall covering is used to line

 

the enclosure, then all measurements

 

must be from the surface of the covering.

2.

Place the appliance into the framing and

 

secure it.

 

Note: If appliance is to be raised above

4. Feed flexible gas line through one of three

gas line conduit sleeve and repack insu-

lation to cover any openings. Prepare the

incoming gas line with teflon tape or pipe

joint compound and hook-up incoming

gas line to the flexible gas line.

Note: If 1/2" NPT black iron pipe does

not mate with fitting at the end of flex-

ible gas line, remove fitting and replace

with a 37 degree flare 3/4"-12, 1/2" NPT

29.5°

9"

(229mm)

6"

(152mm)

12"

(305mm)

6" Min.

(152mm)

3" (76mm)

1 1/2"

(38mm) Max.

Combustible Materials

Header

Spacer

floor level, a platform must be built to

support the appliance.

3. Install the supply line to the appliance

using a 1/2" NPT black iron gas line ter-

minating 2 5/16" above the bottom of the

appliance. The gas line may be installed

from either side or from the rear of the

appliance (see Figure 15, page 9).

(female) fitting.

WARNING: When finishing ap- pliance, Do not overlap combus- tible material onto the black front face. Brick, tile, or other noncom- bustible materials may be applied to the face provided that any gap is between the material used and the face is caulked with a non- combustible caulking.

Figure 5 - Mantel Clearances - Side View (Cross Section)

38 1/8"

(968mm) Min.

15"

(381mm)

1 1/2"

(38mm) Max.

3" (76mm) Max.

6" (152mm) Min.

TOP VIEW

Outer Surround

Combustible

Material May

Be Used

Safe

Zone

33°

Within 12" (305mm)

18" (457mm) Min.

15 5/8" Min. (397mm)

36 1/4"

(921mm) Min.

Figure 7 - Rough Opening for Installing in Wall

417/8"

(1061mm)

21 3/16"

(538mm)

29 5/8"

(752mm)

36 1/4"

(921mm)

59 1/4"

(1505mm)

CORNER INSTALLATION

Figure 8 - Rough Opening for Corner Installation

Figure 6 - Side Clearances - Top View (Cross Section)

107050

5

Image 5
Contents What to do if YOU Smell GAS For Your SafetyEVGL850N Natural Electronic Ignition Vented Type Decorative Appliance Before YOU Begin IntroductionClearances PRE-INSTALLATION PreparationSelecting Location Framing Mantel Clearances and Wall DetailsTypical B-Vent Configuration Venting InstallationMin Roof Pitch Checking for Proper VentingWall Switch Installation EVGL850N InstallationOvertighten GAS Line HOOK-UPGAS Burner Supply HOOK-UP LOG & Ember PlacementAppliance Enclosure Glass Door Removal and ReplacementCombustion AIR KIT Model Akgl Optional Operating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceOperating Guidelines and Maintenance Instructions Pilot Assembly AdjustmentBurner Flame Adjustment Wiring Diagram Service HintsTechnical Service Observed Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at Parts Under Warranty Accessories Replacement PartsReceiver and HAND-HELD Remote Control KIT 00710 WRC Parts not Under WarrantyGAS Control Valve Replacement PartsPilot Assembly 107050 Warranty Information