AIR FOR COMBUSTION AND VENTILATION
Continued
8
DETERMINING AIR FLOW FOR FIREBOX LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install firebox plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height = ___________________ cu. ft. (volume of space)
Example: Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
____________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example: 3168 cu. ft. (volume of space) ÷ 50 cu. ft. = 63.3 or 63,300 (maximum Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
| ___________________ Btu/Hr | |||
Gas water heater* |
| ___________________ Btu/Hr | ||
Gas furnace |
| ___________________ Btu/Hr | ||
Vented gas heater |
| ___________________ Btu/Hr | ||
Gas firebox logs |
| ___________________ Btu/Hr | ||
Other gas appliances* | + ___________________ Btu/Hr | |||
Total | = ___________________ Btu/Hr | |||
Example: Gas water heater |
| 40,000 | Btu/Hr | |
+ |
| 39,000 | Btu/Hr | |
Total | = | 79,000 | Btu/Hr |
*Do not include
4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_________________ | Btu/Hr (maximum the space can support) |
_________________ | Btu/Hr (actual amount of Btu/Hr used) |
Example: 63,300 | Btu/Hr (maximum the space can support) |
79,000 | Btu/Hr (actual amount of Btu/Hr used) |
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A.Rework work sheet, adding the space of an adjoining room. If the extra space pro- vides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air from Inside Building, page 9.
B.Vent room directly to the outdoors. See Ventilation Air from Outdoors, page 9.
C.Install a lower Btu/Hr firebox, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
WARNING
WARNING ICON | G 001 |
If the area in which the firebox and gas log heater may be oper- ated is smaller than that defined as an unconfined space, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3.
103296