Desa M36, M42, VM36, VM42 Troubleshooting, Observed Problem Possible Cause Remedy

Page 21

TROUBLESHOOTING

21

TROUBLESHOOTING

Note: For additional help, visit DESA’s Technical Service web site at www.desatech.com.

Note: Before troubleshooting the system, make sure the gas shutoff valve is ON.

The two most common causes of a malfunctioning gas appliance are:

1.Loose wiring connections

2.Construction debris clogging the pilot and/or gas control valve filter

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Pilot will not light

1.

No gas supply, or shutoff valve is OFF

1.

Check to see if you have gas supply

 

2.

Air in gas line

2.

Hold regulator control valve in the PILOT

 

 

 

 

position for 2 to 3 minutes to purge air. If

 

 

 

 

you smell gas stop and wait for a few min-

 

 

 

 

utes before trying to light the fireplace

 

3.

Construction debris clogging pilot orifice

3.

Remove debris and dirt, inspect and

 

 

 

 

clean any other possible obstructions

 

4.

Low gas pressure

4.

Contact your gas supplier

 

5.

Control valve knob is not on the PILOT

5.

Refer to section on pilot lighting

 

 

position

 

 

 

6.

Kinked pilot line

6.

Have a qualified technician replace pi-

 

 

 

 

lot line

 

7.

Bad valve

7.

Replace regulator valve (see Accesso-

 

 

 

 

ries, page 29)

 

8.

Vent damper not fully open

8.

Open vent damper until fully locked in

 

 

 

 

OPEN position

 

 

 

 

 

Pilot will not stay lit

1.

Loose wiring on thermopile to regula-

1.

Check wiring connections. Refer to wir-

 

 

tor valve. No millivolt current is being

 

ing diagram shown in Wall Switch In-

 

 

sent back to regulator

 

stallation, page 11

 

2.

If valve knob and wall switch are in the

2.

Have a qualified technician replace valve

 

 

ON position, probable defective regula-

 

 

 

 

tor valve

 

 

 

3.

Vent damper not fully open

3.

Open vent damper until fully locked in

 

 

 

 

OPEN position

 

 

 

 

 

No gas to burner, although wall switch and

1.

Wall switch wires defective or too long

1.

Check electrical connections

valve are set to the ON position

2.

Thermopile not generating sufficient

2.

See Pilot will not stay lit, above

 

 

voltage

 

 

 

 

 

 

 

Frequent pilot outage

1.

Pilot flame may be too low, causing

1.

Clean and adjust pilot flame for maximum

 

 

safety pilot to “drop out”

 

flame impingement on thermopile

 

2.

Improper venting or excessive blockage

2.

Have the vent system inspected, includ-

 

 

 

 

ing the termination cap. Remove any

 

 

 

 

restriction or obstruction

For more information, visit www.desatech.com

108795-01H

Image 21
Contents Vent Decorative GAS Fireplace For Your SafetyNatural GAS What to do if YOU Smell GASSafety Information Table of ContentsUnpacking Introduction Before YOU BeginM36B,H/VM36B,H M42B,H/VM42B,H Model Product SpecificationsPRE-INSTALLATION Preparation Selecting LocationClearances M36B,H M42B,H Mantel Clearances and Wall DetailsVM36B,H VM42B,H M36B,H M42B,H VM36B,H VM42B,HFraming Installing Transition Pipe and Starter CollarTypical B-Vent Configuration Venting InstallationMin Roof Pitch Checking for Proper VentingWall Switch Installation InstallationOptional Wireless HAND-HELD Remote Control Installation Installing ReceiverGAS Line HOOK-UP Installing 9-Volt Battery in Hand-Held Remote Control UnitOvertighten Ember and PAN Material PlacementInstalling Logs 3 LOG Placement for M36/VM36 ModelsRest the lower part of log 5 on the log 4 and on LOG Placement for M42/VM42 ModelsInstalling Optional Glass Door Accessory Combustion AIR KIT Model AK4 OptionalAppliance Enclosure Removing Glass Doors Opening Vent DamperOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceInspecting Burners Pilot AssemblyOptional HAND-HELD Remote Operation Burner Flame PatternWiring Diagram Cleaning Maintenance Technical ServiceService Hints Replacement PartsObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Gas leak. See Warning statement at TopVM42B,H Models Illustrated Parts BreakdownUnder Replacement Parts on page 20 of this manual Parts ListLogs for M36B,H, M42B,H, VM36B,H and VM42B,H Models Logset for M36B, H/VM36B, H ModelsLogset for M42B, H/VM42B, H Models Owners Registration Form Postage Required Accessories Warranty Information