Desa M36, M42, VM36, VM42 Combustion AIR KIT Model AK4 Optional, Appliance Enclosure

Page 16

16

INSTALLATION

Combustion Air Kit Model AK4 (Optional)

Appliance Enclosure

Installing Optional Glass Door Accessory

INSTALLATION

Continued

COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)

The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through any outside wall a minimum of three feet below fireplace termination cap. The handle to operate the damper door for the outside air inlet will be located inside the left “screen pocket” of the firebox (see Figure 33). Pull the handle to open or push to close.

CAUTION: Air inlet ducts are not to terminate in attic space.

Screen Pocket

Air Kit

Handle

Figure 33 - Air Kit Handle Location

APPLIANCE ENCLOSURE

Before finishing the enclosure around the appliance, inspect all joints around the outer surround. Any gaps between the nailing flanges and the framing should be sealed with noncombustible insulation or caulking.

If the appliance is mounted on a raised platform, it must be a continuous surface and not on blocks without a solid surface. This will prevent the entry of cold air by means of conduction through the total bottom of the appliance. (see Figure 34).

Side

 

 

Side

Framing

 

 

Framing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Caulk Here

Pack Insulation

Figure 34 - Sealing Between Appliance and Framing

INSTALLING OPTIONAL GLASS DOOR ACCESSORY

CAUTION: Use only glass doors certified for use with this appliance.

Note: Glass door may be heavy for some individuals. If this is the case, please request help from someone else.

The M36, VM36, M42 and VM42 B-vent fireplaces are approved for use with optional bi-fold glass doors (see Accessories, page 29). The glass panels may be ordered and installed anytime after the fireplace installation is complete.

Follow these steps to install left and right panels:

1.With the handle at the bottom, completely fold the panel on its hinges.

2.With the handle facing the center of the firebox opening, in- sert the lower pivot pin on the glass door panel into the hole in pivot plate on the bottom edge of the fireplace opening (see Figure 35).

3.Keeping the folded door tilted, slide the upper two pins into the guide track found under the upper facial edge of the fire- box opening.

4.Tilt the glass assembly fully vertical until the outer pivot pin snaps into the mounting hole in the upper spring clip (see Figure 35).

Slide Top PinSpring Clip

Into Door Track

Insert Pin Into

Spring Clip

Insert Bottom

Pivot Pin Into

Pivot Plate and

Swing Door Into

Vertical Position

Pivot Plate

Figure 35 - Installing Optional Glass Door

For morevisit www..com

108795-01H

Image 16
Contents For Your Safety Vent Decorative GAS FireplaceNatural GAS What to do if YOU Smell GASTable of Contents Safety InformationUnpacking Before YOU Begin IntroductionM36B,H/VM36B,H M42B,H/VM42B,H Product Specifications ModelSelecting Location PRE-INSTALLATION PreparationClearances Mantel Clearances and Wall Details M36B,H M42B,HVM36B,H VM42B,H M36B,H M42B,H VM36B,H VM42B,HInstalling Transition Pipe and Starter Collar FramingVenting Installation Typical B-Vent ConfigurationChecking for Proper Venting Min Roof PitchInstallation Wall Switch InstallationOptional Wireless HAND-HELD Remote Control Installation Installing ReceiverInstalling 9-Volt Battery in Hand-Held Remote Control Unit GAS Line HOOK-UPEmber and PAN Material Placement OvertightenLOG Placement for M36/VM36 Models Installing Logs 3LOG Placement for M42/VM42 Models Rest the lower part of log 5 on the log 4 and onCombustion AIR KIT Model AK4 Optional Installing Optional Glass Door AccessoryAppliance Enclosure Opening Vent Damper Removing Glass DoorsFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To AppliancePilot Assembly Inspecting BurnersOptional HAND-HELD Remote Operation Burner Flame PatternCleaning Maintenance Technical Service Wiring DiagramService Hints Replacement PartsTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Top Gas leak. See Warning statement atIllustrated Parts Breakdown VM42B,H ModelsParts List Under Replacement Parts on page 20 of this manualLogset for M36B, H/VM36B, H Models Logs for M36B,H, M42B,H, VM36B,H and VM42B,H ModelsLogset for M42B, H/VM42B, H Models Owners Registration Form Postage Required Accessories Warranty Information