Desa VC42PE SERIES Removing/Replacing Glass Door, Pressure Testing Fireplace Gas Connections

Page 24

Fireplace

Installation

Continued

Pressure Testing Fireplace Gas

Connections

1. Open equipment shutoff valve (see Figure 33, page 23).

2. Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace.

Removing Louver Panels

Remove the top and bottom louver panels by si- multaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 36). Repeat for bottom spring latches and pull the lou- vers outward. To install or replace items removed, simply reverse the procedures above.

3. Make sure control knob of fireplace is in the OFF position.

4. Check all joints from equipment shutoff valve to gas valve (see Figure 34, page 23, for propane/LP or Figure 35, page 23, for natural gas). Apply noncorrosive leak detection fluid

Louver Panel

Spring Latch

to all joints. Bubbles forming show a leak. Correct all leaks at once.

5. Light fireplace (see Operating Fireplace, page

28). Check all other internal joints for leaks.

6. Turn off fireplace (see To Turn Off Gas to Ap- pliance, page 28).

Removing/Replacing Glass

Door

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part informa- tion see Replacement Parts, page 34.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn off and un- plug fireplace. Let cool before re- moving glass door or louvers.

Figure 36 - Removing Louver Panel

Removing Glass Door

If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame.

1.Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/rod assembly from the fire- box. Set assembly aside.

2.Lift up on latches to unlock. There are two on top of firebox and two below firebox that hold glass door in place (see Figure 37).

3.While holding glass door to prevent it from falling and causing injury, remove the five screws from the hinge located on the left side of door frame assembly (see Figure 37).

Unlock Lock

Latch

Screw

Hinge

Glass Frame

Assembly

Figure 37 - Removing/Replacing Glass

Door

24

www.desatech.com

116237-01E

Image 24
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product IdentificationHigh traffic areas Product Features Pre-Installation PreparationLocal Codes Location and space requirementsClearances 42 1067 mmFront 36 914 mm Top of Standoffs Vent See venting Venting clearancesFraming and finishing Noncombustible mantels at any height aboveFireplace Location of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Corner Installation Recommended Applications Corner ground floor installationHorizontal System Installation Using TWO 90 Elbows Installation for vertical termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe High Altitude Installation Vertical VentingParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionFireplace Installation Installing optional blower accessoriesModel BK Installation Plug in blower power cordModel BKT Installation Blower Model BKTInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Connecting Fireplace to GAS Supply Propane/LP Supply TankExternal Regulator Vent Pointing DownChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPaClose equipment shutoff valve see Figure Disconnect fireplace and its individual equipPressure Testing Fireplace Gas Connections Removing/Replacing Glass DoorRemoving Louver Panels Removing Glass DoorInstalling lava rock and glowing embers Installing Brick liner Models BL42DASA and BL42DHASACleaning Glass Door Wall Switch Installation Optional Remote control Installation model WRCReplace top and bottom louvers Wiring Diagram For your safety Read before lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceOperating optional blower accessory Pilot AssemblyInspecting Burners Optional Remote OperationCleaning Maintenance Glass DoorPilot and burners LogsTroubleshooting Observed Problem Possible Cause RemedyVenting system Check wiring connection Ule And/or check ground wire toNo gas to burner, although wall Wall switch wires defective Pilot will not stay litStatement at top Gas leak. See WarningReplacement Parts Service HintsTechnical Service SpecificationsAccessories Illustrated Parts Breakdown Models VC42NE, VVC42NE, VC42PE and VVC42PEParts List 2827 19 18 Burner Pan Assembly Warranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace