PARTS LIST

Models TC36N, VTC36N, TC36P and VTC36P Series

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 37 of this manual.

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

1

**

Firebox Assembly

2

**

Face Weldment

3

108010-01

Door Assembly

4

108011-01

Top Louver Assembly

5

108011-02

Bottom Louver Assembly

6

**

Fireplace Top

7

**

Fireplace Top Insulation

8

**

Fireplace Surround

9

109082-01

Heat Shield

10

116217-01

Log Set Assembly

11

See Below

Left Refractory Brick Panel

12

See Below

Rear Refractory Brick Panel

13

See Below

Right Refractory Brick Panel

14

108719-01

Screen Rod

15

12105

Screen

16

11418

Push-On Nut

17

14123

Strain Relief

18

21171

Gas Knock-Out Cover

19

24353

Handy Box Assembly

20

24460

Gas Conduit Assembly

21

116209-01

Burner Assembly (Natural Gas)(See page 40)

 

116209-02

Burner Assembly (Propane/LP Gas) (See page 40)

 

116211-05

Burner Assembly for High Altitude Models (See page 40)

22

116373-01

Plenum

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

 

 

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

1

2

1

1

1

1

1

1

25487

Lava Rock/Bag Assy

27253

Notice Label

55240

Vent Label

** Part not available for field replacement.

REFRACTORY BRICK PANELS

TC36NB VTC36NB

TC36NB-HA VTC36NB-HA

TC36PB VTC36PB DESCRIPTION

110989-02

110989-01

Left Refractory Brick Panel

110991-02

110991-01

Rear Refractory Brick Panel

110990-02

110990-01

Right Refractory Brick Panel

QTY

1

1

1

1

1

1

116192-01E

www.desatech.com

39

Image 39
Contents What to do if YOU Smell GAS Table of Contents Safety Information High traffic areas Product IdentificationLocation and space requirements Product FeaturesPre-Installation Preparation Local CodesVenting clearances Clearances42 1067 mm Front 36 914 mm Top of Standoffs Vent See ventingFraming and finishing Noncombustible mantels at any height aboveFireplace Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Snorkel Termination InstallationHorizontal System Installation Using TWO 90 Elbows Installation for vertical termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsPlug in blower power cord Fireplace InstallationInstalling optional blower accessories Model BK InstallationBlower Model BKT Model BKT InstallationInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Propane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyDisconnect fireplace and its individual equip Checking GAS ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Close equipment shutoff valve see FigureTurn off fireplace see To Turn Off Gas to Ap- pliance, Installing optional wall Mount Switch gwmS2Pressure Testing Fireplace Gas Connections Installing Remote ReceiverRemoving/Replacing Glass Door Removing Louver PanelsRemoving Glass Door Installing lava rock and glowing embers Installing Brick liner Models BL36DASA and BL36DHASACleaning Glass Door Close top and bottom louvers For your safety Read before lightingOperating Fireplace Lighting InstructionsRemote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Hand-HeldThermostat Series Model HRC200 On/Off Series Model HRC100Inspecting Burners Operating optional blower accessoryPilot assembly Key Pad Lock FeatureCleaning Maintenance Burner Flame PatternGlass Door Pilot and burners LogsVenting system Observed Problem Possible Cause Remedy TroubleshootingLong enough Control knob pressed Problem could be caused by Or replace pilot assemblyBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasCold Minute Air in gas line Operate burner until air is When burner is lit HI position when burner isOr shut off Service person Remote does not function Tery power is lowStatement above Specifications Replacement PartsService Hints Technical ServiceModels TC36N, VTC36N, TC36P and VTC36P Series Illustrated Parts BreakdownParts List 19 18 116192-01E Burner Pan Assembly Accessories Wall mounted thermostat control kit gwmt1 Not Shown Wall mounted on/off switch gwmS2 Not ShownWarranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace