Desa VS36(1), S36RH, S36H Optional Gas Line Installation, Typical Residential Installations

Page 11

Venting Installation

Continued

EFFECTIVE HEIGHT OF TERMINATION CAP

14.5FT.

MINIMUM HEIGHT

EFFECTIVE HEIGHT OF TERMINATION CAP

14.5FT.

MINIMUM HEIGHT

UP TO 6FT.

MAXIMUM

EFFECTIVE HEIGHT OF

TERMINATION CAP

MAXIMUM

HEIGHT

50 FT.

(ANY SYSTEM)

UP TO 6 FT.

MAXIMUM

30E-8DM

EFFECTIVE HEIGHT OF

TERMINATION CAP

MINIMUM HEIGHT OF 22 FT. (WITH TWO ELBOW SETS) MAXIMUM HEIGHT OF 50 FT.

30E-8DM

Figure 18 - Typical Residential Installations

Optional Gas Line

Installation

Gas line hook up should be done by your supplier or a qualified service person.

Note: Before you proceed, make sure your gas supply is turned off.

Use only a 1/2" black iron pipe and appropriate fittings.

1.Remove knockout indentation on refractory or firebrick wall located above the refractory hearth floor. The knockout indentation must be firmly tapped with any solid object such as a 1/2" dowel until it is released. Remove fragmented portions of refractory (see Figure 19).

2.Remove gas line cover plate located on either side of fireplace and pull out insulation from gas line conduit sleeve. Save insulation for reuse. Replace screws.

3.Run a 1/2" black iron gas line into the fireplace through the rear at gas line conduit sleeve (if using a raised platform, add height). Provide sufficient gas line into fireplace chamber for fitting connection (see Figure 20, page 12). Note: Secure incoming gas line to wood framing to provide rigidity for threaded end.

4.Repack insulation around gas line and into sleeve opening. Seal any gaps between gas line and refractory knockout hole with refractory ce- ment or commercial furnace cement, Install the gas appliance or cap-off gas line if desired.

Outside of

Side

Firebrick

Fireplace

Finished

 

Gas Line

Side

 

Conduit

 

Insulation

1/2" Dowel

 

Gas

 

Conduit

Refractory

Cover

Knockout

 

 

Plug

Figure 19 - Gas Line Knockout

111026-01C

www.desatech.com

11

Image 11
Contents Models S36, S36H, S36R, S36RH, VS361 and VS36H1 Save this BookSafety Information Table of ContentsSpecifications Framing Fireplace InstallationSelecting location Minimum clearance to combustiblesMantels Drain Pan DP36Hearth Extension Chimney Pipe Venting InstallationAssembly and installation of double wall chimney system Optional Outside air Kit Model ak4/ak4fElbow SET only Using Elbow offsets 30E-8DM Penetrating the roof Firestop Spacers V3600FS-8DMTerminations/Spark Arrestor Flashing installation v6f-8dm or v12f-8dmInstalling Flashing on a Metal Roof Finishing the fireplace Chase installationsFoot rule Typical Residential Installations Optional Gas Line InstallationGlass Doors Operation Maintenance GuidelinesOutside air and damper handle operation Technical ServiceCleaning the Glass Illustrated Parts Breakdown Refractory Brick Parts ListAccessories Replacement Parts111026-01C 111026-01C 111026-01C Not a UPC