Desa S36RH, S36H Venting Installation, Optional Outside air Kit Model ak4/ak4f, Chimney Pipe

Page 6

Venting Installation

Optional Outside air Kit (Model ak4/ak4f)

The installation of an outside air kit should be per- formed during the rough framing of the fireplace due to the nature of it's location. Outside combus- tion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4).

CAUTION: Combustion air inlet ducts shall not terminate in attic space.

Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size)

Air Inlet

Location

Must Allow

For Bushes

or Snow

 

Air Inlet

 

Eyebrow

Vented Crawl Space

Vent Hood

Required for

(Check Local Codes

Wall Installation

Before Installing in a

 

Vented Crawl Space)

 

Figure 5 - Outside Air Kit

Chimney Pipe

The DESA chimney system consists of 12", 18", 24", 36" and 48" snap-lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fitting overlaps must be taken into consideration (lineal gain) and are given in the lineal gain chart (see Figure 6). Lineal gain is the actual measurable length of a part after two or more parts are connected. For Canada, use chimney parts designated "HT".

WARNING: The opening in the collar around the chimney at the top of the fireplace must not be obstructed.Neveruseblowninsula- tion to fill the chimney enclosure.

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

36"

Fireplace

40"

12-8DM

Pipe Section

10 5/8"

12-8HT

 

 

18-8DM

Pipe Section

16 5/8"

18-8HT

 

 

24-8DM

Pipe Section

23 5/8"

24-8HT

 

 

36-8DM

Pipe Section

34 5/8"

36-8HT

 

 

48-8DM

Pipe Section

46 5/8"

48-8HT

 

 

RT-8DM

Round Termination

6 7/8"*

RTL-8DM

Round Termination

7 3/4"*

RTT-8DM

Round Termination

6 7/8" to

with Slip Section

23 1/8"*

 

RTTL-8DM

Round Termination

8 1/2" to

with Slip Section

21 1/2"*

 

ET-8DM

Square Chase-Top

12"*

ETO-8DM

Square Chase-Top

12"*

 

with Mesh

 

ETL-8DM

Square Chase-Top

7" to 15"*

 

with Slip Section

 

 

Square Chase-Top

12" to

ETLO-8DM

with Mesh & Slip

25 1/2"*

 

Section

 

 

*The lineal gain for the terminations is mea- sured to the flue gas outlet height.

12" Galvanized

Outer Pipe

12 3/8"

Hemmed

Stainless

End

 

Inner Pipe

 

Figure 6 - Lineal Gain

Assembly and installation of double wall chimney system

Each double wall chimney section consists of a galvanized outer pipe, a stainless steel inner flue pipe and a wire spacer. The pipe sections must be as- sembled independently as the chimney is installed. When connecting chimney directly to the fireplace, the inner flue pipe section must be installed first with the lanced side up. The outer pipe section can then be installed over the flue pipe section with the hemmed end up. Press down on each pipe section until the lances securely engage the hem on the fire- place starter. The wire will assure the proper spacing between the inner and outer pipe sections.

www.desatech.com111026-01C

Image 6
Contents Save this Book Models S36, S36H, S36R, S36RH, VS361 and VS36H1Table of Contents Safety Information Specifications Minimum clearance to combustibles Fireplace InstallationSelecting location FramingDrain Pan DP36 Hearth ExtensionMantels Optional Outside air Kit Model ak4/ak4f Venting InstallationAssembly and installation of double wall chimney system Chimney PipeUsing Elbow offsets 30E-8DM Elbow SET onlyFirestop Spacers V3600FS-8DM Penetrating the roofFlashing installation v6f-8dm or v12f-8dm Installing Flashing on a Metal RoofTerminations/Spark Arrestor Chase installations Foot ruleFinishing the fireplace Optional Gas Line Installation Typical Residential InstallationsOperation Maintenance Guidelines Glass DoorsTechnical Service Cleaning the GlassOutside air and damper handle operation Illustrated Parts Breakdown Parts List Refractory BrickReplacement Parts Accessories111026-01C 111026-01C 111026-01C Not a UPC