Desa S36RH, VS36H(1), VS36(1) Operation Maintenance Guidelines, Glass Doors

Page 12

Optional Gas Line

Installation

Continued

CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPER- ATE ANYAPPLIANCE IF A LEAK IS DETECTED. LEAK TESTING SHOULD BE DONE BYA QUALI- FIED SERVICE PERSON.

Note: A DESA hood must be installed when using an unvented gas log set (see Accessories on page 16).

WARNING: Do not oper- ate an unvented gas log set in this fireplace with the chimney removed.

If you install a decorative gas appliance (vented gas log), the decorative gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces, ANS Z21.60, Z21.84 or RG 2-72and shall also be installed in accordance with the National Fuel Gas Code, ANSI 7223NFPA 54 latest edition.

Outside of

 

Side

Fireplace

 

Firebrick

Gas

Incoming

Finished

Side

Line

1/2" Black

 

Conduit

Iron Pipe

 

 

Seal

 

Repack

Opening

 

with

 

Insulation

Refractory

 

Cement

Provide Enough Threaded

End for Fitting Connection

Figure 20 - Gas Line Installation

WARNING:Toavoidtheriskof damagingthe fireplace materials andincreasingtheriskofspread- ing a fire, do not use the fireplace to cook or warm food.

WARNING: If the fireplace has been used for wood burning, the firebox and chimney must be cleaned of soot, creosote and ashes be a qualified chimney cleaner. Creosote will ignite if heavily heated.

WARNING: When using a decorative vented gas log, the damper must be removed or per- manently locked in the fully open positionandtheglassdoorsmust be in the fully open position.

Operation and

Maintenance

Guidelines

Glass Doors

Glass doors are optional with the fireplace. When the fireplace is in operation, doors must be fully opened or fully closed position only or a fire hazard may be created (see Figure 21).

Doors Fully Closed

Fireplace Front

Doors

Fully Opened

Fireplace Front

Figure 21 - Glass Doors

12

www.desatech.com

111026-01C

Image 12
Contents Save this Book Models S36, S36H, S36R, S36RH, VS361 and VS36H1Table of Contents Safety InformationSpecifications Fireplace Installation Selecting locationMinimum clearance to combustibles FramingDrain Pan DP36 Hearth ExtensionMantels Venting Installation Assembly and installation of double wall chimney systemOptional Outside air Kit Model ak4/ak4f Chimney PipeUsing Elbow offsets 30E-8DM Elbow SET onlyFirestop Spacers V3600FS-8DM Penetrating the roofFlashing installation v6f-8dm or v12f-8dm Installing Flashing on a Metal RoofTerminations/Spark Arrestor Chase installations Foot ruleFinishing the fireplace Optional Gas Line Installation Typical Residential InstallationsOperation Maintenance Guidelines Glass DoorsTechnical Service Cleaning the GlassOutside air and damper handle operation Illustrated Parts Breakdown Parts List Refractory BrickReplacement Parts Accessories111026-01C 111026-01C 111026-01C Not a UPC

VS36H(1), S36H, VS36(1), S36RH, S36 specifications

The Desa S36R, S36, S36RH, VS36(1), and S36H are notable products in the world of heating solutions, specifically designed to enhance warmth and comfort in various environments. Each model comes with distinct features, technologies, and characteristics aimed at meeting diverse heating needs.

The Desa S36R stands out for its robust design and efficiency. It incorporates state-of-the-art burner technology that ensures a clean and efficient burn, maximizing heat output while minimizing energy consumption. The S36R also features adjustable heat settings, allowing users to tailor the warmth according to their preferences. Its compact size makes it suitable for different settings, whether in residential spaces or workshops.

The Desa S36 model further enhances these attributes with a focus on user-friendly operation. It includes an electronic ignition system, ensuring effortless startup. Additionally, the S36 is equipped with safety features like an automatic shut-off mechanism, which provides peace of mind for users. The durable construction ensures long-lasting use, making it a reliable choice for consistent heating.

For those needing mobility, the Desa S36RH is the ideal option. Its portable design allows for easy transportation, making it suitable for both indoor and outdoor applications. The S36RH emphasizes versatility, coming with multiple fuel options such as propane, which not only diversifies its usability but also accommodates various user preferences.

The VS36(1) model takes innovation a step further with advanced technology integration. It features Wi-Fi connectivity, enabling users to control the heater remotely using a smartphone app. This smart functionality not only adds convenience but also allows for precise temperature management, optimizing energy efficiency. The VS36(1) is characterized by its sleek design, which complements modern home aesthetics while delivering powerful heating performance.

Lastly, the Desa S36H is tailored for high-performance heating in larger spaces. It boasts a powerful output and advanced airflow technology that enhances heat distribution, making it suitable for both residential and commercial applications. The S36H is designed with user comfort in mind, featuring simple controls and a robust design that withstands rigorous use.

In summary, the Desa S36R, S36, S36RH, VS36(1), and S36H models showcase a range of innovative features, efficient technologies, and characteristics suited for various heating requirements. Their focus on safety, efficiency, and user convenience makes them standout choices in the heating solutions market. Whether for home, workshop, or outdoor use, Desa provides reliable options that cater to diverse consumer needs.