Desa VMH26TNB installation manual Inspecting Burner

Page 18

® VMH26TNB

COMPACT CLASSIC HEARTH FIREPLACE

OPERATING

FIREPLACE

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostatic control used on this fire- place differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this fireplace senses the room tempera- ture. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature.

The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb mea- sures the temperature of air near the fireplace cabinet. This may not always agree with room temperature (depend- ing on housing construction, installation location, room size, open air tempera- tures, etc.). Frequent use of your fire- place will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, page 17.

2.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, page 17.

OPERATING BLOWER

This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF posi- tion, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature.

Note: Your fireplace and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.

Auto/Off/On Switch

ON

OFF

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 31 shows a correct pilot flame pattern. Figure 32 shows an incorrect pilot flame pattern. The incorrect pilot flame is not prop- erly heating the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the fireplace will shut down.

If pilot flame pattern is incorrect, as shown in Figure 32

turn fireplace off (see To Turn Off Gas to Appliance)

see Troubleshooting, pages 20 through 22

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Thermocouple

Pilot Burner

Figure 31 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

Figure 32 - Incorrect Pilot Flame Pattern

Figure 30 - Auto/Off/On Switch

18

107029

Image 18
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Compact Classic Hearth FireplaceUnpacking Product FeaturesProduct Identification Local CodesAssembling Fireplace AssemblyInstalling Log Assembling HoodUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstallation Items Locating FireplaceBUILT-IN Fireplace Installation Locate fireplace where moving vehicle will not hit itOptional Mantel Installation Mantel Clearances for Built-In InstallationInstalling Blower Assembly Installing Blower Accessory GA3450TRemoving Upper Louver Assembly Assembling Brass Trim Brass trim shipped with mantelInstall the switch plate on the valve For Built-In Installation Wiring Diagram For Blower Accessory Built-In InstallationConnecting to GAS Supply Extension CordAttaching Wood Base to Solid Floor Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burner Burner Flame Pattern Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole CabinetTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Service Hints SpecificationsReplacement Parts Technical ServiceIllustrated Parts Breakdown VMH26TNB17Parts List VMH26TNBAccessories 107029 Warranty Information

VMH26TNB specifications

The Desa VMH26TNB is a versatile and innovative heating appliance designed to meet the demands of modern home environments. This unit combines cutting-edge technology with practical features to provide efficient heating solutions for various spaces.

One of the key highlights of the VMH26TNB is its impressive heat output. With a powerful capacity, it can effectively heat large areas, making it ideal for living rooms, open-concept spaces, or even commercial settings. Its heating efficiency is bolstered by the incorporation of advanced thermal conduction materials that ensure maximum warmth with minimal energy consumption.

Another notable feature of the Desa VMH26TNB is its user-friendly control system. Equipped with a digital thermostat, this model allows users to set their desired temperature with precision. The intuitive interface provides real-time feedback, enabling users to monitor their energy usage and adjust settings accordingly for optimal comfort.

The VMH26TNB is also designed with safety in mind. It includes multiple safety features, such as overheat protection and a tip-over switch that automatically shuts off the unit in case it tips over. These features are crucial in preventing accidents, making this heater a reliable addition to any home.

In terms of technology, the Desa VMH26TNB stands out with its energy-efficient operation, which is compliant with modern energy standards. It uses a combination of infrared and convection heating methods that distribute warmth evenly throughout the room. This dual heating technology not only enhances comfort but also reduces energy costs.

Additionally, the unit is designed with aesthetics in mind. Its sleek and contemporary design allows it to blend seamlessly with various interior styles, making it not just a functional appliance but also an attractive element of home decor.

Lastly, ease of maintenance is another characteristic that enhances the desirability of the VMH26TNB. Its filter is easily accessible for cleaning, ensuring that the device operates at peak performance over time.

In summary, the Desa VMH26TNB is a powerful, efficient, and safe heating solution that caters to modern heating needs while providing style and convenience. Its blend of advanced technology and thoughtful design makes it an excellent choice for both residential and commercial applications.