CAUTION: If you install the fireplace in a home garage

fireplace pilot and burner must be at least 18 inches above floor.

locate fireplace where moving vehicle will not hit it.

For convenience and efficiency, install fireplace

where there is easy access for operation, inspection, and service.

in coldest part of room.

An optional blower kit is available from your dealer. See Accessories, page 26. If planning to use blower, locate fireplace near an electrical outlet.

BUILT-IN FIREPLACE

INSTALLATION

Built-in installation of this fireplace involves installing fireplace into a framed-in enclo- sure. This makes the front of fireplace flush with wall. An optional brass trim kit acces- sory is available (see Accessories, page 26). Brass trim will extend past sides of fireplace approximately 1/2 inch. This will cover the rough edges of the wall opening. If install- ing a built-in mantel above the fireplace you must follow the clearances shown in Figure 12, page 10. Follow the instructions below to install the fireplace in this manner.

 

Actual

Framing

 

 

 

Height

26"

26 7/8"

 

 

 

Front Width

26 3/4"

26 7/8"

 

 

 

Depth

9 1/2"

10 1/2"

 

 

 

Bottom

3/4"

3/4"

 

 

 

1.Frame in rough opening. Use dimen- sions shown in Figure 9 for the rough opening.

If installing in a corner, use dimensions shown in Figure 10 for the rough open- ing. The height is 26 7/8" which is the same as the wall opening above.

2.If installing GA3450T blower acces- sory, do so at this time. Follow instruc- tions included with blower accessory.

Note: If not installing blower acces- sory, you may wish to run electrical wiring to your fireplace for future blower installation (see Accessories, page 26) Use only approved three-wire electrical wiring.

WARNING: If pre-wiring, do not connect wiring to any electri- cal source at this time.

Install fireplace electrical outlet and connect wiring to outlet be- fore connecting to electrical source. The fireplace electrical outlet is included with the GA3450T blower accessory.

Only use the fireplace electrical outlet supplied with the GA3450T blower accessory.

Note: A qualified installer should make all electrical connections.

3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping.

10 1/2"

267/8"

3/4" Off

The Floor

267/8" Minimum

Figure 9 - Rough Opening for Installing in Wall

365/8"

257/8"

267/8" 513/4"

Figure 10 - Rough Opening for Installing in Corner

4.If you have not assembled firebox, fol- low instructions on page 4.

5.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

6.Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, page 15.

7.Bend four nailing flanges on outer cas- ing with pliers (see Figure 11).

8.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange.

9.Check all gas connections for leaks. See Checking Gas Connections, page 16.

10.If using optional brass trim kit, install the trim after final finishing and/or painting of wall. See instructions in- cluded with brass trim accessory for at- taching brass trim.

IMPORTANT: When finishing your fire- box, combustible materials such as wall board, gypsum board, sheet rock, drywall, plywood, etc. may be butted up next to the sides and top of the firebox. Combustible materials should never overlap the firebox front facing.

WARNING: Do not allow any combustible materials to overlap the firebox front facing.

Nails or

Wood

Screws

Nailing

Flanges

Figure 11 - Attaching Fireplace to Wall Studs

Continued

107029

9

Image 9
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualCompact Classic Hearth Fireplace Safety InformationProduct Identification Product FeaturesUnpacking Local CodesInstalling Log AssemblyAssembling Fireplace Assembling HoodProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating FireplaceLocate fireplace where moving vehicle will not hit it BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationRemoving Upper Louver Assembly Installing Blower Accessory GA3450TInstalling Blower Assembly Assembling Brass Trim Brass trim shipped with mantelInstall the switch plate on the valve Wiring Diagram For Blower Accessory Built-In Installation For Built-In InstallationConnecting to GAS Supply Extension CordAttaching Wood Base to Solid Floor Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burner Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceBurner Flame Pattern CabinetObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Replacement Parts SpecificationsService Hints Technical ServiceVMH26TNB17 Illustrated Parts BreakdownVMH26TNB Parts ListAccessories 107029 Warranty Information

VMH26TNB specifications

The Desa VMH26TNB is a versatile and innovative heating appliance designed to meet the demands of modern home environments. This unit combines cutting-edge technology with practical features to provide efficient heating solutions for various spaces.

One of the key highlights of the VMH26TNB is its impressive heat output. With a powerful capacity, it can effectively heat large areas, making it ideal for living rooms, open-concept spaces, or even commercial settings. Its heating efficiency is bolstered by the incorporation of advanced thermal conduction materials that ensure maximum warmth with minimal energy consumption.

Another notable feature of the Desa VMH26TNB is its user-friendly control system. Equipped with a digital thermostat, this model allows users to set their desired temperature with precision. The intuitive interface provides real-time feedback, enabling users to monitor their energy usage and adjust settings accordingly for optimal comfort.

The VMH26TNB is also designed with safety in mind. It includes multiple safety features, such as overheat protection and a tip-over switch that automatically shuts off the unit in case it tips over. These features are crucial in preventing accidents, making this heater a reliable addition to any home.

In terms of technology, the Desa VMH26TNB stands out with its energy-efficient operation, which is compliant with modern energy standards. It uses a combination of infrared and convection heating methods that distribute warmth evenly throughout the room. This dual heating technology not only enhances comfort but also reduces energy costs.

Additionally, the unit is designed with aesthetics in mind. Its sleek and contemporary design allows it to blend seamlessly with various interior styles, making it not just a functional appliance but also an attractive element of home decor.

Lastly, ease of maintenance is another characteristic that enhances the desirability of the VMH26TNB. Its filter is easily accessible for cleaning, ensuring that the device operates at peak performance over time.

In summary, the Desa VMH26TNB is a powerful, efficient, and safe heating solution that caters to modern heating needs while providing style and convenience. Its blend of advanced technology and thoughtful design makes it an excellent choice for both residential and commercial applications.