Desa VMH26TNB Connecting to GAS Supply, Extension Cord, Attaching Wood Base to Solid Floor

Page 14

® VMH26TNB

COMPACT CLASSIC HEARTH FIREPLACE

INSTALLATION

Continued

Extension Cord

Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An undersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

Attaching Wood Base to Solid Floor

For attaching base to solid floors (concrete or masonry)

Note: Floor anchors and mounting screws are in hardware package. The hardware package is provided with fireplace.

1.

Drill holes at marked locations using

 

5/16" drill bit. For solid floors (con-

 

crete or masonry), drill at least 1" deep.

2.

Fold floor anchor as shown in Figure 22.

3.

Insert floor anchor (wings first) into

 

hole. Tap anchor flush to floor.

4.

Insert mounting screws through base

 

and into floor anchors.

WARNING: Never connect fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

IMPORTANT: Check gas line pressure be- fore connecting fireplace to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, fireplace regulator damage could occur.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" or greater diameter to al- low proper gas volume to fire- place. If pipe is too small, un- due loss of volume will occur.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 23).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

WARNING: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 23. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

5. Tighten screws until base is firmly fas-

tened to floor.

Figure 22 - Folding Anchor

CONNECTING TO GAS SUPPLY

WARNING: This appliance re- quires a 45° male flare fitting 5/8"- 18 UNF (Unified National Fine Thread) inlet connection and the flexible gas line provided.

CSA Design-Certified

Equipment Shutoff

Valve With 1/8" NPT

Tap*

From Gas Meter (5" W.C. to 10.5" W.C. Pressure)

3" Minimum

Pipe Nipple Cap Tee Joint

Sediment Trap

Figure 23 - Gas Connection

WARNING: A qualified ser- vice person must connect fire- place to gas supply. Follow all local codes.

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 26.

14

107029

Image 14
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Compact Classic Hearth FireplaceUnpacking Product FeaturesProduct Identification Local CodesAssembling Fireplace AssemblyInstalling Log Assembling HoodUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Locating FireplaceBUILT-IN Fireplace Installation Locate fireplace where moving vehicle will not hit itOptional Mantel Installation Mantel Clearances for Built-In InstallationInstalling Blower Assembly Installing Blower Accessory GA3450TRemoving Upper Louver Assembly Assembling Brass Trim Brass trim shipped with mantelInstall the switch plate on the valve For Built-In Installation Wiring Diagram For Blower Accessory Built-In InstallationAttaching Wood Base to Solid Floor Connecting to GAS SupplyExtension Cord Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Inspecting Burner Burner Flame Pattern Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole CabinetTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Service Hints SpecificationsReplacement Parts Technical ServiceIllustrated Parts Breakdown VMH26TNB17Parts List VMH26TNBAccessories 107029 Warranty Information

VMH26TNB specifications

The Desa VMH26TNB is a versatile and innovative heating appliance designed to meet the demands of modern home environments. This unit combines cutting-edge technology with practical features to provide efficient heating solutions for various spaces.

One of the key highlights of the VMH26TNB is its impressive heat output. With a powerful capacity, it can effectively heat large areas, making it ideal for living rooms, open-concept spaces, or even commercial settings. Its heating efficiency is bolstered by the incorporation of advanced thermal conduction materials that ensure maximum warmth with minimal energy consumption.

Another notable feature of the Desa VMH26TNB is its user-friendly control system. Equipped with a digital thermostat, this model allows users to set their desired temperature with precision. The intuitive interface provides real-time feedback, enabling users to monitor their energy usage and adjust settings accordingly for optimal comfort.

The VMH26TNB is also designed with safety in mind. It includes multiple safety features, such as overheat protection and a tip-over switch that automatically shuts off the unit in case it tips over. These features are crucial in preventing accidents, making this heater a reliable addition to any home.

In terms of technology, the Desa VMH26TNB stands out with its energy-efficient operation, which is compliant with modern energy standards. It uses a combination of infrared and convection heating methods that distribute warmth evenly throughout the room. This dual heating technology not only enhances comfort but also reduces energy costs.

Additionally, the unit is designed with aesthetics in mind. Its sleek and contemporary design allows it to blend seamlessly with various interior styles, making it not just a functional appliance but also an attractive element of home decor.

Lastly, ease of maintenance is another characteristic that enhances the desirability of the VMH26TNB. Its filter is easily accessible for cleaning, ensuring that the device operates at peak performance over time.

In summary, the Desa VMH26TNB is a powerful, efficient, and safe heating solution that caters to modern heating needs while providing style and convenience. Its blend of advanced technology and thoughtful design makes it an excellent choice for both residential and commercial applications.