Hearth and Home Technologies GO35MTCH, GO40MTCH Lighting Instructions- Match Light

Page 17

T. Lighting Instructions- Match Light

WARNING

Asphyxiation Risk

Gas-burning appliances produce smoke and carbon monoxide gas during operation.

The damper must be open

The chimney must draw properly

These fumes can be harmful if not vented properly.

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING! IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.This appliance has a manually lighted burner and must be lit by hand. When lighting the burner, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.

D.Use only your hand to push in or turn the gas control handle. Never use tools. If the handle will not push in or turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in fire or explosion.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information previously listed above.

2.Turn gas control manual valve to the full “OFF” position.

3.Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step.

4.Place a lit match on the surface of the burning embers. Do not hold match in hand.

5.Turn gas control manual valve to the full “ON” position.

6.If appliance will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

Turn manual gas control handle to “OFF” position. Do not force.

(Place lit match in ember bed before turning on valve)

(Located in wall or floor near fireplace)

Valve

Valve Key

Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08

17

Image 17 Contents
Commonwealth of Massachusetts What to do if you smell gasModel # Serial # Gas Type Homeowner Reference InformationListing Label Information/Location Fire Risk Exhaust Fumes Risk Design and Installation ConsiderationsTools and Supplies Needed Gas Supply Connection Appliance CertificationGas Pressure Fire Risk Explosion RiskNegative Pressure For Minimum Fireplace DimensionsAsphyxiation Risk For Factory Built FireplacesInspect the Appliance and Components For Natural Gas InstallationFire Risk Explosion Risk Personal Injury Risk Damper Stop Installation InstructionsPossible cures if spilling occurs Inspect the Venting SystemGO24 Grand Oak Series Logs GO24 Grand Oak Series Log Placement Instructions GO30 Grand Oak Series Logs Step GO30 Grand Oak Series Log Placement InstructionsGO35 Grand Oak Series Logs GO35 Grand Oak Series Log Placement Instructions SRV721A SRV721B GO40 Grand Oak Series LogsGO40 Grand Oak Series Log Placement Instructions Lighting Instructions- Match Light For Your Safety Read Before LightingDo not allow soot to build up on the logs Cleaning and Maintenance InstructionsFequently Asked Questions What sort of maintenance do gas logs require?Grand Oak Gas Logs Replacement PartsDescription of Part Qty Decorative GAS LOG Limited Warranty WarrantyDIS CNO