Hearth and Home Technologies GO40MTCH, GO35MTCH Inspect the Appliance and Components

Page 6

H. Inspect the Appliance and Components

Remove the contents from the carton labeled “Burner”. Attached to the burner are tags identifying the manufacturer name, serial number, model number (including gas log size), BTU ratings, gas type, etc.

Review the attached tags before proceeding. Ensure that all minimum fireplace dimension requirements are achieved using Table 3. See Figure 1. Ensure the gas type provided in the fireplace coincide with the gas type marked on the tag.

I. For Natural Gas Installation

Pour sand into the burner pans to the point where the burner pipe is covered. See Figure 3. Level the sand from right to left to ensure an even flame pattern. At this point the pan should be half full.

Figure 1 Measure Firebox

The burner is assembled with the controls installed at the factory and is designed to connect one end of the 3/8 in. supply line before placing inside the fireplace. Ensure the connection is tightened using a 3/4 in. wrench.

Place the burner towards the rear and center of the fireplace and connect to the gas line. Follow instructions in “F. Gas Pressure” to check for gas leaks.

Install the grate by placing the inserts (attached to the grate) into the slots provided in the burner pan. Slide the inserts into the slots (See Figure 2) and push the grate as far as possible to the locked position.

Figure 2

Placing Grate

Figure 3

Sand

.Pour vermiculite over the sand in the pans until they are full. See Figure 4.

Figure 4 Placing Vermiculite

Note: For best results, do not pack down the rock wool. The placement of rock wool can have an effect on flame pattern and may need to be adjusted to achieve a desired appearance.

Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08

Image 6
Contents What to do if you smell gas Commonwealth of MassachusettsHomeowner Reference Information Listing Label Information/LocationModel # Serial # Gas Type Design and Installation Considerations Tools and Supplies NeededFire Risk Exhaust Fumes Risk Gas Pressure Appliance CertificationGas Supply Connection Fire Risk Explosion RiskAsphyxiation Risk For Minimum Fireplace DimensionsNegative Pressure For Factory Built FireplacesFor Natural Gas Installation Inspect the Appliance and ComponentsDamper Stop Installation Instructions Fire Risk Explosion Risk Personal Injury RiskInspect the Venting System Possible cures if spilling occursGO24 Grand Oak Series Logs GO24 Grand Oak Series Log Placement Instructions GO30 Grand Oak Series Logs GO30 Grand Oak Series Log Placement Instructions StepGO35 Grand Oak Series Logs GO35 Grand Oak Series Log Placement Instructions GO40 Grand Oak Series Logs SRV721A SRV721BGO40 Grand Oak Series Log Placement Instructions For Your Safety Read Before Lighting Lighting Instructions- Match LightCleaning and Maintenance Instructions Do not allow soot to build up on the logsWhat sort of maintenance do gas logs require? Fequently Asked QuestionsReplacement Parts Grand Oak Gas LogsDescription of Part Qty Warranty Decorative GAS LOG Limited WarrantyDIS CNO