Lennox Hearth E36ODGPE-H New York and Massachusetts requirements, General Information, All Models

Page 3

New York and Massachusetts requirements

These appliances may be installed in the following USA locations with the following requirements:

Installation of these appliances are approved for installation in the US state of Massachu- setts if the following additional requirements are met -

Installation and repair must be done by a plumber or gas fitter licensed in the Common- wealth of Massachusetts.

The flexible gas line connectors shall not exceed 36 inches (92 centimeters) in length.

The individual manual shut-off must be a t-handle type valve.

General Information

Note: Installation and repair should be per- formed by a qualified service person. The appli- ance should be inspected annually by a qualified professional service technician. More frequent inspections and cleanings may be required due to yard care, insects, etc. It is imperative that the control compartment and burners of the appliance be kept clean.

Provide adequate clearances around air open- ings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.

These appliances are designed to operate on natural or propane gas only.

All Models -

All models have a manually modulated gas valve. Input is shown in Table 1:

Models with Manually-Modulated Gas Valve

Natural Gas

Propane Gas

 

Input

 

Input

Model No.

rate

Model No.

rate

 

(Btu/H)

 

(Btu/H)

 

50,000

 

46,000

E36ODG

to

E36ODG

to

 

39,500

 

37,000

 

50,000

 

46,000

E42ODG

to

E42ODG

to

 

39,500

 

37,000

Table 1

Gas Pressure - All Models

Tables 2 and 3 show the appliances' inlet and manifold gas pressure.

Inlet Gas Supply Pressure

(all models)

Fuel #

Minimum

Maximum

Natural Gas

5.0" WC

10.5" WC

(1.24 kPa)

(2.61 kPa)

 

 

 

 

Propane

11.0" WC

13.0" WC

(2.74 kPa)

(3.23 kPa)

 

 

 

 

Table 2

Manifold Gas Supply Pressure

(all models)

Fuel #

Low

High

Natural Gas

(Lo) 2.2" WC

(Hi) 3.5" WC

(.55 kPa)

(.87 kPa)

 

 

 

 

Propane

(Lo) 6.3" WC

(Hi) 10.0" WC

(1.57 kPa)

(2.49 kPa)

 

 

 

 

Table 3

Test gage connections are provided on the front of the gas control valve identified IN for the inlet and OUT for the manifold side. A 1/8" NPT Test gauge connection is provided at the inlet and outlet side of the electronic gas control valve.

These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

These appliances and their individual shut-off valves must be disconnected from the gas sup- ply piping system during any pressure testing of that system at pressures greater than 1/2 psig (3.5 kPa).

Orifice Sizes - Sea Level To High Altitude (All Models)

These appliances are tested and approved for installation at elevations of 0-4500 feet (0-1372 meters) above sea level, using the standard burner orifice (See Table 4 ). For elevations above 4500 feet, contact your gas supplier or qualified service technician. Install the appli- ance according to the regulations of the local authorities having jurisdiction and, in the USA, the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition or , in Canada, the CAN1- B149.1 and .2 codes - latest edition.

Model

Orifice size

Elevation

Natural

 

Feet

No.

Propane

 

Gas

(meters)

E36OdG

0.1405"

0.0785"

 

(#28)

(#47)

0-4500

 

 

 

 

E42OdG

0.1405"

0.0785"

(0-1372)

(#28)

(#47)

 

 

 

 

 

 

 

Table 4

Warning: Propane tanks are at pressures that will cause dam- age to valve components. Verify that the tanks have step down regulators to reduce the pres- sure to safe levels.

Image 3
Contents Consumer Retain this manual for future reference Outdoor GAS Fireplace 850,034M REV. D 04/2009OTL Report No -F-41-5 Table of Contents Gas Pressure All Models New York and Massachusetts requirementsGeneral Information All ModelsLocation of fireplace Assembly outline Before You StartPre-installation notes Assembly steps47 /4 Drain Connector detailClearances X /2Clearance specifications Fireplace Installation Routing Gas Line-3/4 44 mm 4 95 mm Right Side Only Top Stand-OffSpacers Places Umbilical CordUnfinished Shown Parallel Installation Back WallBack Wall Materials If AnyField Wiring SwitchWeather Seal Cover Valve Connecting Gas LineTop Right Log Installing the logsRear Log Base Log Top Left LogSee Note 29 Min Checking Appliance OperationFirebox Finishes Minimum For Combustible MaterialsDrain Pan Installation Accessories And ComponentsRemove Clip Shutter Opening Orifice Regulator Gas Conversion KitsNatural to Propane Gas Conversion Kit Propane to Natural Gas Conversion KitIgnitor Electronic AppliancesRefer to on ELECtrONIC PILOt Pilot Sensor
Related manuals
Manual 16 pages 24.92 Kb

E42ODGPE-H, E42ODGNE-H, E42ODGPE, E36ODGNE, E36ODGPE specifications

Lennox Hearth gas fireplaces are designed to offer both aesthetics and performance, making them a popular choice for homeowners seeking warmth and ambiance. The models E36ODGNE-H, E42ODGNE, E36ODGPE-H, E36ODGPE, and E36ODGNE stand out due to their innovative features and advanced technologies, ensuring efficiency while enhancing the overall look of any space.

One of the most significant features of these fireplaces is their impressive heating capacity. The E36ODGNE-H and E42ODGNE models provide substantial warmth, making them suitable for various room sizes. With a maximum BTU output reaching up to 40,000, they can effectively heat your living space while creating a comfortable environment. Additionally, the option for variable fan speed allows for consistent and efficient heat distribution, ensuring that every corner of the room remains cozy.

The design of Lennox Hearth fireplaces is both stylish and functional. The sleek glass doors provide a clear view of the flames, and the modern aesthetic can complement a variety of interior designs. With customizable finish options, homeowners can tailor their fireplace to match their decor, making it a focal point in their living space.

Another remarkable aspect of these models is their user-friendly control options. The integrated remote control allows for easy operation, letting users adjust flame height and fan speed with the push of a button. This convenience enhances the overall experience, allowing for seamless enjoyment of the fireplace.

Safety is also a priority in the design of Lennox Hearth fireplaces. These models come equipped with safety features such as an automatic shut-off system and a glass door that remains cool to the touch, ensuring that users can enjoy their fireplace without worry.

The efficiency of Lennox Hearth fireplaces is evident in their remarkable thermal efficiency ratings. These units are designed to maximize energy use, resulting in lower operating costs while still providing abundant warmth. This eco-friendly approach aligns with modern energy-saving standards, making these fireplaces an attractive choice for environmentally conscious consumers.

In summary, Lennox Hearth’s E36ODGNE-H, E42ODGNE, E36ODGPE-H, E36ODGPE, and E36ODGNE models present an intriguing combination of style, efficiency, and safety. Whether you are looking to enhance your home’s interior or seeking an effective heating solution, these fireplaces deliver the performance and elegance that discerning homeowners desire.