ODGSR Series Outdoor Gas Fireplace
Troubleshooting
Nova SIT 820 Standing Pilot
START
Gas Supply On
YES
Pilot Lights with
Piezo Ignitor
YES
Pilot Stays Lit
YES
Pilot Lights Main
Burner
YES
|
| CHECK |
NO |
| Supply Line Hooked up |
| ||
|
| Shutoff Valve Open |
Lockout has engaged. Wait 60 seconds and try again.
Piezo not tight enough for good ground.
NO For spark at electrode while depressing Piezo (Red Button) 1/8" gap to pilot hood needed.
All wiring connections Replace Piezo Ignitor Thermodisk
For Air in the lines Thermopile needs a minimum
325mV. Adjust pilot flame height. All wiring connections
NO Replace Thermopile Thermocouple needs a minimum
of 14mV.
Defective valve. Turn to pilot, meter should read greater than 100mV.
Thermodisk
Wall switch is not turned on. Watch for grounded wires!
NO Thermopile needs a minimum 325mV
Plugged burner orifice Doors not fully open (Fig. 10)
System OK
FP396