Vermont Casting ODGSR42A, ODGSR36A manual Gas Line Installation, Parts identification

Page 7

 

FP1414

Fig. 5

Valve access.

 

Majestic Logo

 

Brick

 

FP1415

Fig. 6

Lift brick with logo on it to access valve.

ODGSR Series Outdoor Gas Fireplace

The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa).

If gas piping from the source to the appliance location has not been accomplished, install the required pipe. Consult local plumbing code to assure proper pipe size.

The gas pipeline can be brought in through the right side of the appliance. A knockout is provided to allow for the gas pipe installation and testing of any gas con- nection.

NOTE: The gas line connection can be made with 3/8" copper tubing approved for propane or natural gas, 1/2" rigid pipe or an approved flex connector, then reduced to 3/8" to the appliance. Because some municipalities have some additional local codes, it is always best to consult your local authority.

U.S.: Consult the current National Fuel Gas Code, ANSI Z223.1/NFPA 54.

Canada: CSA - B149.1 installation code.

Test for leaks. Use a 50/50 solution of liquid soap and water to test for leaks at gas fittings and joints. Apply water/soap solution with brush only - do not over apply. NEVER test with an open flame.

The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to pro- vide a 1/8" test point up stream of the control.

Nailing

Flange

FP1416

*Do not install header until unit is in place.

Standoff

Surround

Gas Line Ac- cess

Screen

Grate

Firebox

Valve Access Panel

When using copper or flex connector use only approved fittings. Always provide a union so that gas line can be easily disconnected for burner or fan servicing.

See gas specification for pressure details and ratings. NOTE: If flex connector is used, it must be kept inside of the appliance. (Fig. 8)

1/2" Gas Supply

1/2" x 3/8" Shut-off Valve

3/8" Nipple

3/8" Union

3/8" Nipple

Fig. 7 Parts identification.

Gas Line Installation

This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure equal to or less than 1/2 psig (3.45 kPa).

FP598

Fig. 8 Typical gas supply installation.

20007114

7

Image 7
Contents ODGSR36A, ODGSR42A Table of Contents Enclosures for LP-Gas Supply Systems General InformationDescription Fireplace Dimensions Hearth Screened Porch InstallationClearance to Combustibles Mantels\Gas Specification Valve AccessFraming and Finishing FinishingParts identification Gas Line InstallationCorrect door position during operation Remote Wall SwitchOperating Instructions Log InstallationFirst Firing Flame Characteristics Flame AdjustmentNova SIT Pilot Optional Weather Enclosure Installation InstructionsOptional Stainless Steel Hood To Turn Off Gas to Heater Lighting and Operating InstructionsStart TroubleshootingBurner and Burner Compartment MaintenanceCleaning Cleaning the Standing Pilot Control SystemODGSR42A Logs 4a/b 12a/b 19a/b DescriptionODGSR36A, ODGSR42A Accessory Description Model Number AccessoriesOdgsr Series Outdoor Gas Fireplace Limited Lifetime Warranty CFM Corporation