American Standard CERATRONIC Proximity Faucet with Touch-Free Temperature Control, 6058.105

Page 8

2HOW TO CLEAN FILTER; Fig. 2

CAUTION Before opening ENCLOSURE disconnect AC power supply.

1.Remove ENCLOSURE COVER.

2.Close SUPPLY STOPS.

Note: Keep water flowing out of faucet while shutting off.

4.Unthread STRAINER (1) using a 7/16" socket.

5.Pull out the STRAINER (1) and clean with an old toothbrush. Rinse thoroughly with water.

6.Install the STRAINER (1) back in its place and tighten with a 7/16" socket.

Caution: do not over tighten strainer.

Note: It is recommended to clean strainer every 6 months.

7.Replace ENCLOSURE COVER. Tighten cover screws firmly.

3HOW TO CLEAN AND REMOVE THE AERATOR; Fig. 3

1.Remove AERATOR HOUSING (1) with KEY (2) supplied with faucet.

3.Remove AERATOR (3) from HOUSING (1). Fig. 3a.

2.Clean the AERATOR SCREENS (4) with a old tooth brush to remove dirt.

4.Rinse Clean with water. Reassemble and install into spout end. Be sure the black seal washer is in place.

Fig. 2

1

CLEAN

SCREENS 1

INSTALL

REMOVE

Fig. 3

Fig.5

1

REMOVE

2

Fig. 3a

4

3

7

M968857 REV. 1. 2

Image 8
Contents Installation Instructions Unpacking ProductInstall Spout Assembly Fig InstallationRoughing-in Dimensions Connect Hoses to Wall Supply Fig Mount Enclosure FigConnect Spout Hose to Enclosure Fig Electrical Installation Handwash Sensor Operation Fig HOW to Change ON/OFF Sensor Range Factory set at 6 a, 2bOperation Maintenance HOW to Remove Mixing Valve FigHOW to Clean Filter Fig HOW to Clean and Remove the Aerator FigFaqs General Cleaning FigCeratronic M968857 REV