T R O U B L E S H O O T I N G G U I D E |
| |||
Problem |
| Possible Causes | Corrective Action | |
|
|
|
| |
Burner will not light | • Blocked Venturi tubes | • Clean out blockage | ||
(match or igniter) |
|
|
| |
• Cylinder or gas supply valve turned off | • Open cylinder or gas supply valve | |||
| ||||
Burners not hot enough |
|
|
| |
• Venturi tubes not properly sealed over orifices | • Ensure proper Venturi assembly | |||
| ||||
|
|
|
| |
| • Burner ports blocked | • Clean / replace burner | ||
|
|
|
| |
| • Low or out of propane | • Refill cylinder | ||
|
|
|
| |
| • Regulator safety devise must be | • Follow How to Reset the Gas | ||
|
|
| Regulator Safety Device (page 5) | |
|
|
|
| |
| • Regulator not fully tightened into cylinder | • Tighten regulator fully (hand tighten) onto cylinder | ||
|
|
| • Straighten fuel hose | |
|
|
| ||
Flames smoky yellow | • Partially blocked Venturi tubes | • Clean out blockage | ||
|
|
|
| |
| • Excess cooking salts on burner | • Clean burner | ||
|
|
| ||
Burner lights with match | • Loose wire connection | • Check all connections are tight | ||
but not with igniter |
|
|
| |
• Broken electrode | • Ensure collector box, burner and | |||
| ||||
| • Poor ground | igniter are assembled properly | ||
|
|
|
| |
| • Faulty igniter | • Replace igniter | ||
|
|
| ||
Flame blows out / down | • High wind conditions | • Relocate barbecue back towards wind | ||
through base |
|
|
| |
• Propane low | • Refill cylinder | |||
| ||||
|
|
| ||
Too much heat / excessive | • Excessive fat in meat | • Trim meat, turn down burner controls | ||
|
| and / or fuel supply | ||
|
|
|
| |
| • Grease drain plugged | • Clean casting base and burner | ||
|
|
|
| |
| • Cooking system not positioned correctly | • Position cooking system correctly | ||
|
|
| ||
Flames under heat | • Blocked Venturi tubes | • Immediately shut off gas at source, | ||
control console |
|
| allow grill to cool and clean out Venturi tubes | |
|
|
| ||
Regulator humming | • This is not a defect or a hazard | • Temporary condition caused by high outside | ||
|
|
| temperatures and a full propane cylinder | |
|
|
| ||
Incomplete flame | • Plugged, rusted or leaking burner | • Clean / replace burner | ||
|
|
| ||
Warming rack | • Legs are angled too narrowly, or widely | • The warming rack legs are adjustable. | ||
will not fit |
|
| Please bend to fit into the warming rack holes | |
|
|
|
|
For more troubleshooting support or parts ordering, please call toll free
9