LP Tank Exchange
•Many retailers that seii griiis offer you the option of replacing your empty LPtank through an exchange service. Use only those reputable exchange companies that inspect, precision fill, test and certify their cylinders. Exchange your tank only for an OPD safety
•Always keep new and exchanged LPtanks in upright position during use, transit or storage.
•Leak test new and exchanged LPtanks BEFORE connecting to grill.
Connecting Regulator To The LP Tank
1.LPtank must be properly secured onto grill. (Refer to assembly section.)
2.Turn all control knobs to the OFF position.
3.Turn LPtank OFF by turning OPD hand wheel clockwise to a full stop.
4.Remove the protective cap from LPtank valve. Always use cap and strap supplied with valve.
LP Tank Leak Test
For your safety
•Leak test must be repeated each time LPtank is exchanged or refilled.
•Do not smoke during leak test.
•Do not use an open flame to check for gas leaks.
•Grill must be leak tested outdoors in a
•Use a clean paintbrush and a 50/50 mild soap and water solution. Brush soapy solution onto areas indicated by arrows in figure below. Leaks are indicated by growing bubbles.
If "growing" bubbles appear do not use or move the LP
tank. Contact an LPgas supplier or your fire department!
•Do not use household cleaning agents. Damage to the gas train components (valve/hose/regulator) can result.
Hand Wheel
rpe 1 outlet with thread on outside
Safety Relief
/
Strap and Cap
Do not insert a POL transport plug
(plastic part with external
threads)! into the type 1 valve
outlet. It will defeat the Safety Relief Valve feature.
5.Hold regulator and insert nipple into LP tank valve.
Nipple has to be centered into the LP
tank val
16153- 50300312 • 5