A. EARTH CONTINUITY CHECK

Appliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjust zero if necessary.

Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 W (Ohm), check all earth wires for continuity and all contacts clean and tight.

B.INSULATION CHECK

Appliance electrically disconnected, all switches ON.

a)meter set on W (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on W (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than × (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component.

It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

Image 24
Contents 65852 G Welcome to the world of Electrolux Contents Important Safety Information InstallationChild Safety During UseService ∀ Environmental InformationAny new owner Installation Description of the HobsOperation Hob burners control knobsLighting the burners Using the hob correctly Burner Minimum Maximum DiameterUsing the Wok Stand Quale bruciatore suggerisre per la gri- glia WOK qui?Maintenance and Cleaning Hob TopPan Supports Burners Ignition electrodeSymptom Solution Something Not Working?Instructions for the Installer Engineer technical dataAeration adjustment none Important safety requirements LocationInstallation Gas Connection Cut Out Size BuildingBuilding over a cupboard or drawer Building over a kitchen unit with door Fitting the Hob into the Worktop Electrical connections This HOB Must be EarthedWiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Ignitor does not sparkPressure Testing Minimum adjustment screwCommissioning Conversion from Natural Gas to LPG MethodGuarantee/Customer Service Standard guarantee conditionsExclusions Service and Spare Parts Customer Care0870 5 929 European Guarantee