Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.

!1) Turn the gas tap to the MAX position and ignite.

2)Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.

Procedure:

!1) Re-ignite the burner and set to MIN.

2) Remove the control knob.

3) To adjust, use a thin bladed screwdriver and turn the adjustment screw (see diagram) until the flame is steady and does not extinguish, when the knob is turned from MIN to MAX. Repeat this procedure for all burners.

Pressure Testing

Minimum adjustment screw

The pressure testing must becarried out on the burners.

!Proceed as follows:

1)Remove the pan supports andthe burner caps and crowns.

2)Fit manometer tube over the injector.

3)Turn on the burner gas supply and ignite another burner supply.

The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar.

4)Turn off the burner supplies.

Image 26
Contents 65852 G Welcome to the world of Electrolux Contents Child Safety Important Safety InformationInstallation During UseAny new owner Service∀ Environmental Information Installation Description of the HobsLighting the burners OperationHob burners control knobs Using the hob correctly Burner Minimum Maximum DiameterUsing the Wok Stand Quale bruciatore suggerisre per la gri- glia WOK qui?Pan Supports Maintenance and CleaningHob Top Burners Ignition electrodeSymptom Solution Something Not Working?Instructions for the Installer Engineer technical dataAeration adjustment none Important safety requirements LocationInstallation Gas Connection Building over a cupboard or drawer Cut Out SizeBuilding Building over a kitchen unit with door Fitting the Hob into the Worktop Electrical connections This HOB Must be EarthedWiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Ignitor does not sparkCommissioning Pressure TestingMinimum adjustment screw Conversion from Natural Gas to LPG MethodExclusions Guarantee/Customer ServiceStandard guarantee conditions 0870 5 929 Service and Spare PartsCustomer Care European Guarantee