3D Connexion V300 user manual Freq Hz 1820 Thru Slope dB/oct Filter Shape Linkwitz Riley

Page 16

13.3 Biamp System Parameters

Parameter

Unit/Name

Low Section

High Section

 

 

 

 

Gain

(dB)

0

-6

Delay

(ms)

0

0

Polarity

 

Positive

Positive

 

 

 

 

HPF â

Freq (Hz)

45.1

1920

 

Slope (dB/oct)

24

24

 

Filter Shape

Butterworth

Linkwitz Riley

 

 

 

 

LPF

Freq (Hz)

1820

Thru

 

Slope (dB/oct)

24

NA

 

Filter Shape

Linkwitz Riley

NA

 

 

 

 

PEQ 1 â

Freq (Hz)

60.1

6100

 

Level (dB)

+7

+3.5

 

Type

Parametric

Hi - Shelf

 

Q / Bandwidth

2.8 / 0.3536

NA

 

 

 

 

PEQ 2

Freq (Hz)

281

10500

 

Level (dB)

-2.5

+4

 

Type

Parametric

Parametric

 

Q / Bandwidth

2 / 0.500

9.5 / 0.1051

 

 

 

 

PEQ 3

Freq (Hz)

749

NA

 

Level (dB)

-2

NA

 

Type

Parametric

NA

 

Q / Bandwidth

2 / 0.500

NA

 

 

 

 

PEQ 4

Freq (Hz)

606

NA

 

Level (dB)

-2

NA

 

Type

Parametric

NA

 

Q / Bandwidth

6 / 1.669

NA

 

 

 

 

PEQ 5

Freq (Hz)

1650

NA

 

Level (dB)

-2

NA

 

Type

Parametric

NA

 

Q / Bandwidth

7.1 / 0.1403

NA

 

 

 

 

âNote : When using the V300 with subs, set HPF on LF section @ 80 – 100Hz (24dB/oct LR) and omit PEQ1 (on LF only)

PEQ 1 (on LF only) may also be omitted when using the V300 as a floor monitor.

Image 16
Contents Page Contents Introduction Connectors/CablingUnpacking 11.0 17.0100 17.0 35.0 11.0 22.0 14.0 Polarity Checking Crossovers Amplification & Power HandlingEqualisation 60deg ArrayingDimensions V300Rigging & Suspension General Safety Advice Secur ET VMY Yoke Bracket Number on Assembly View Fig Description Quantity Page Secur ET VEB Eyebolt Secur ET VCS Ceiling Saddle Secur ET VTH Pole MountSecur ET VPC Pole Clamp Must be adhered to for optimum performance Delay Passive System Parameters optionalParameter Unit/Name Gain PolarityFreq Hz 1820 Thru Slope dB/oct Filter Shape Linkwitz Riley 14. V300 Service Parts & Accessories Part Number Description WarrantyDeclaration of Conformity EMCV300