Electrical connection
,CAUTION: Before installation or servicing, disconnect the power supply by either removing the fuse, shutting off the main power supply or manually "tripping" the circuit breaker.
Installation work and repairs should only be performed by a qualified technician in accordance with all applicable codes and standards. Repairs and service by unqualified persons could be dangerous and the manufacturer will not be held responsible.
Before connecting the appliance to the power supply, make sure that the voltage and frequency listed on the data plate correspond with the household electrical supply. This data must correspond to prevent appliance damage. Consult an electrician if in doubt.
Only operate the combiset after it has been installed into the countertop.
Installer:
Please leave these instructions with the consumer.
Power supply
^Be sure your electrical supply matches the data plate.
The combiset is equipped with a flexible metal conduit encasing 3 wires ready for connection to a grounded power supply.
A dedicated line and junction box should be used to connect the combiset to a 15 A circuit.
Black wire: connect to L1 (hot)
Red wire: connect to L2 (hot)
Green wire: connect to GND (ground)
240 V, 60 Hz, 15 A fuse rating.
Be sure the power outlet is accessible after installation.
For further information, see the wiring diagram provided with the appliance.
,WARNING:
THIS APPLIANCE MUST BE GROUNDED!
33