Weber 43028 manual Connecting the Liquid Propane Cylinder, To Connect the hose to the cylinder

Page 12

12

GAS INSTRUCTIONS

 

CONNECTING THE LIQUID PROPANE CYLINDER

WARNING: Make sure that the LP cylinder valve is closed. Close by turning valve clockwise.

DANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. Sparks or flames will result in a fire or explosion which can cause serious bodily injury or death, and damage to property.

Some LP tanks have differing top collar assembles. (The top collar is the metal protective ring around the valve.) One series of tanks mount with the valve facing front. The other tanks mount with the valve facing away from the fuel scale. These types of tanks are illustrated below.

You will need: LP cylinder, a soap and water solution and a rag or brush to apply it.

1)Make sure hose and regulator are in retaining clip.

DANGER

Failure to use retaining clip could result in gas leaks, fire or explosion which can cause serious bodily injury or death, and damage to property.

2) Turn the LP cylinder so the opening of the valve is either to the front, side or rear of the Weber® gas fi replace. Lift and hook the cylinder onto the fuel gauge.

3)Loosen the cylinder lock wing nut. Swing the cylinder lock down. Tighten the wing nut.

To Connect the hose to the cylinder:

4)Remove the plastic dust cover from the valve.

5)Screw the regulator coupling onto the tank valve, clockwise, or to the right. Hand-tighten only.

Note: This is a new type of connection. It tightens clockwise and will not allow gas to flow unless the connection is tight. The connection requires tightening by hand only.

WARNING: Do not use a wrench to tighten the connection. Using a wrench could damage the regulator coupling and could cause a leak.

6) Mix soap and water.

7) Turn on the cylinder valve.

8)Check for leaks by wetting the fi tting with the soap and water solution and watching for bubbles. If bubbles form, or if a bubble grows, there is

a leak.

If there is a leak, turn off the gas and tighten the fi tting. Turn the gas back on and recheck with the soap and water solution.

If leak does not stop, contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®. Do not use the fi replace.

Installation and repair should be done by a qualifi ed service person. The

replace should be inspected before use and at least annually by a qualifi ed service person. More frequent cleaning may be required as necessary.

It is imperative that control compartment, burners and circulating air passageways of the fi replace be kept clean.

9)When leak checking is complete, turn gas supply OFF at the source and rinse connections with water.

Image 12
Contents Weber Flametm Liquid Propane GAS Units only Warranty / General Instructions For Installation in CanadaCustomer Service Center Roselle Road, Suite Schaumburg, IL For replacement parts callCleaning General InstructionsOperating Storage AND/OR NON USE Exploded View Exploded View List Parts List Assembly Hand tighten only Wrench tighten ALL nuts at this time Assembly / GAS Instructions Important LP Cylinder InformationCheck That the Burner Valve is OFF Connecting the Liquid Propane Cylinder To Connect the hose to the cylinderGAS Instructions GAS Instructions Refilling the Liquid Propane CylinderChecking the Fuel Level in Your Tank Safe Handling Tips for Liquid Propane GAS CylindersLiquid Propane LP Cylinder Liquid Propane Cylinder requirementsCanada Liquid Propane Cylinder requirements Operating Instructions LightingTo Extinguish Operating Instructions Remove the rain shieldsTroubleshooting Problem Check CureMaintenance Annual MaintenanceMain Burner Cleaning Procedure Weber Spider / Insect ScreenMain Burner Flame Pattern Ignition System