Weber 43028 manual Operating Instructions, Remove the rain shields

Page 17

OPERATING INSTRUCTIONS

17

MANUAL LIGHTING

 

 

 

 

1) Remove the rain shields.

1.

 

 

 

 

 

 

 

DANGER

 

 

 

 

Failure to remove rain shields while igniting the

 

 

 

 

fireplace’s burners, or not waiting 5 minutes to allow

 

 

 

 

the gas to clear if the fireplace does not light, may

 

 

4.

6.

result in an explosive flame-up which can cause

 

 

serious bodily injury or death.

 

 

 

 

2) Make sure the burner control knob is turned OFF. (Push knob down and

2.

5.

 

 

turn clockwise to ensure it is in the off position.)

 

 

 

 

WARNING: The burner control knob must be in the

 

 

 

 

OFF position before turning on the liquid propane

 

 

 

 

cylinder valve. If it is not in the OFF position, when

 

 

 

 

you turn on the LP cylinder valve, the “excess gas

 

 

 

 

flow control” feature will activate, limiting the flow

 

 

 

 

of gas from the LP cylinder. If this should occur, turn

 

 

 

 

OFF the LP tank valve and burner control knob. Then

 

 

 

 

start over.

 

 

 

 

DANGER

 

 

 

3.

When the “excess gas flow control” feature is

 

 

 

activated, a small amount of gas is still flowing to the

 

 

 

 

burner. After turning OFF the cylinder and burner

 

 

 

 

control knob, wait at least 5 minutes for the gas to

 

 

 

 

clear before attempting to light the fireplace. Failure to

 

 

 

 

do so may result in an explosive flame-up, which can

 

 

 

 

cause serious bodily injury or death.

 

 

 

 

3)Turn the cylinder on by turning the cylinder valve counterclockwise.

4)Insert match holder with lit match near the center of the burner area.

WARNING: Do not lean over open fireplace.

5)Push burner control knob down and turn to START/HI.

6)Make sure that the burner is lit.

TO EXTINGUISH

Push in the burner control knob and turn clockwise to the OFF posi- tion. Turn gas supply OFF at the source. When unit has cooled, replace rain shields.

WARNING: If the burner does not light, turn the burner control knob to OFF and wait 5 minutes to let the gas clear before you try again or try to light with a match.

Note: Normal burning pattern will develop light soot on log set. If heavy sooting occurs, refer to troubleshooting.

Image 17
Contents Weber Flametm Liquid Propane GAS Units only For Installation in Canada Warranty / General InstructionsCustomer Service Center Roselle Road, Suite Schaumburg, IL For replacement parts callOperating Storage AND/OR NON USE CleaningGeneral Instructions Exploded View Exploded View List Parts List Assembly Hand tighten only Wrench tighten ALL nuts at this time Check That the Burner Valve is OFF Assembly / GAS InstructionsImportant LP Cylinder Information To Connect the hose to the cylinder Connecting the Liquid Propane CylinderGAS Instructions Refilling the Liquid Propane Cylinder GAS InstructionsChecking the Fuel Level in Your Tank Safe Handling Tips for Liquid Propane GAS CylindersCanada Liquid Propane Cylinder requirements Liquid Propane LP CylinderLiquid Propane Cylinder requirements To Extinguish Operating InstructionsLighting Remove the rain shields Operating InstructionsProblem Check Cure TroubleshootingAnnual Maintenance MaintenanceMain Burner Cleaning Procedure Weber Spider / Insect ScreenIgnition System Main Burner Flame Pattern