Weber 43028 manual GAS Instructions

Page 13

 

GAS INSTRUCTIONS

13

CHECK FOR GAS LEAKS

(1)

 

 

 

DANGER

 

Do not use an open flame to check for gas leaks. Be

 

sure there are no sparks or open flames in the area

 

while you check for leaks. Sparks or open flames will

 

result in a fire or explosion, which can cause serious

 

bodily injury or death and damage to property.

 

 

WARNING: You should check for gas leaks every time

(2)

 

 

 

you disconnect and reconnect a gas fitting.

 

Note - All factory-made connections have been thoroughly checked for gas

 

leaks. The burner has been flame-tested. As a safety precaution however,

 

you should recheck all fittings for leaks before using your Weber® Gas Fire-

 

place. Shipping and handling may loosen or damage a gas fitting.

 

 

WARNING: Perform these leak checks even if your

 

 

fireplace was dealer or store assembled.

 

You will need: a soap and water solution, and a rag or brush to apply it.

 

Note - Since some leak test solutions, including soap and water, may be

(3)

slightly corrosive, all connections should be rinsed with water after checking

 

for leaks.

 

To perform leak checks: open cylinder valve by turning the cylinder valve

 

hand-wheel counterclockwise.

 

 

WARNING: Do not ignite burner when leak checking.

 

Check for leaks by wetting the connections with the soap and water solution

 

and watching for bubbles. If bubbles form or if a bubble grows, there is a

 

leak.

 

Check:

(4)

1) Regulator-to-Cylinder connection.

 

 

WARNING: If there is a leak at connection (1) or (2),

 

 

retighten the fitting by hand only, and recheck for

 

 

leaks with soap and water solution. If a leak persists

 

 

after retightening the fitting, turn OFF the gas. DO

 

 

NOT OPERATE THE FIREPLACE. Contact the Customer

 

 

Service Representative in your area using the contact

 

 

information on our web site. Log onto www.weber.com®.

 

Check:

 

2)

Hose-to-regulator.

 

3) Hose to bulkhead fi tting.

 

4)

Bulkhead fi tting.

 

WARNING: If there is a leak at connections (2), (3), or (4), turn OFF the gas. DO NOT OPERATE THE FIREPLACE. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber. com®.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

Image 13
Contents Weber Flametm Liquid Propane GAS Units only For Installation in Canada Warranty / General InstructionsCustomer Service Center Roselle Road, Suite Schaumburg, IL For replacement parts callGeneral Instructions CleaningOperating Storage AND/OR NON USE Exploded View Exploded View List Parts List Assembly Hand tighten only Wrench tighten ALL nuts at this time Important LP Cylinder Information Assembly / GAS InstructionsCheck That the Burner Valve is OFF To Connect the hose to the cylinder Connecting the Liquid Propane CylinderGAS Instructions Refilling the Liquid Propane Cylinder GAS InstructionsChecking the Fuel Level in Your Tank Safe Handling Tips for Liquid Propane GAS CylindersLiquid Propane Cylinder requirements Liquid Propane LP CylinderCanada Liquid Propane Cylinder requirements Lighting Operating InstructionsTo Extinguish Remove the rain shields Operating InstructionsProblem Check Cure TroubleshootingAnnual Maintenance MaintenanceMain Burner Cleaning Procedure Weber Spider / Insect ScreenIgnition System Main Burner Flame Pattern