Maintenance

Weber® Spider /Insect screens

Your Weber® gas barbecue, as well as any outdoor gas appliance, is a target for spiders and other insects. They can nest in the venturi section(1) of the burner tubes. This blocks the normal gas flow, and can cause the gas to flow back out of the air shutter. This could result in a fire in and around the air shutters, under the control panel, causing serious damage to your barbecue.

(1)

The burner tube air shutter is fitted with a stainless steel screen(1) to prevent spiders and other insects access to the burner tubes through the air shutter openings.

(1)

We recommend that you inspect the Spider/Insect screens at least once a year. (See Section “Annual Maintenance”.) Also inspect and clean the the Spider/ Insect screens if any of the following symptoms should ever occur:

1)The smell of gas in conjunction with the burner flames appearing yellow and lazy.

2)Barbecue does not reach temperature.

3)Barbecue heats unevenly.

4)One or more of the burners do not ignite.

￿DANGER

Failure to correct the above mentioned symptoms may result in a fire, which can cause serious bodily injury or death, and cause damage to property.

Annual Maintenance

Inspection and cleaning of the Spider/Insect screens To inspect the spider/insect screens, remove the control panel. If there is dust or dirt on the screens, remove the burners for cleaning the screens. Refer to Maintenance, Replacing Main Burners. Brush the spider/inspect screens, lightly, with a soft bristle brush (i.e. an old toothbrush).

￿CAUTION: Do not clean the spider/insect screens with hard or sharp tools. Do not dislodge the spider/insect screens or enlarge the screen openings.

E200.a

Lightly tap the burner to get debris and dirt out of the burner tube. Once the spider/insect screens and burners are clean replace the burners.

If the spider/insect screen becomes damaged or cannot be cleaned, call Weber-Stephen Products Customer Service for replacement parts.

Main Burner Flame Pattern

The Weber® gas barbecue burners have been factory set for the correct air and gas mixture. The correct flame pattern is shown.

1)Burner tube

2)Tips occasionally flicker yellow

3)Light blue

4)Dark blue

(1)

(2)

(3)

(4)

If the flames do not appear to be uniform throughout the burner tube, follow the burner cleaning procedures.

Main Burner Cleaning Procedure

Turn off the gas supply. Remove the manifold. Look inside each burner with a flashlight.

Clean the inside of the burners with a wire (a straightened- out coat hanger will work). Check and clean the air shutter opening at the ends of the burners. Check and clean the valve orifices at the base of the valves. Use a Steel bristle brush to clean outside of burners. This is to make sure all the burner ports are fully open.

￿CAUTION: Do not enlarge the burner ports when cleaning.

E-1

Image 28
Contents N E S I S LP Gas Grill Owners GuideLiquid Propane GAS Units only Contents Warranty USAGeneral Instructions Storage and/or NonuseCleaning CookingExploded View Exploded View List Parts List Unpacking Ba201.d Page Page B205LP.b Page Page Page 1011 Page Gas Instructions Regulator coupling and could cause a leak Connection. Using a wrench could damageTo Connect the hose to the cylinder Use the barbecue. Replace using only Weber Remove control panel and burner control knobsBarbecue for nicks, cracking, abrasions or cuts. If Hose is found to be damaged in any way, do notCustomer Service Representative in your region using GRILL. Contact the Customer ServiceRepresentative in your region using the contact Attendant, who fills the cylinder by weightAttendant, who fills the tank by weight. Improper Contact the Customer Service Representative in yourRegion using the contact information sheet provided Cylinder valve before disconnectingLighting Operating InstructionsTo Extinguish Manual Lighting Troubleshooting Problem Check CureMaintenance Annual MaintenanceMain Burner Cleaning Procedure Weber Spider /Insect screensReplacing Main Burners Crossover Ignition System Operations