Weber 55553 manual Replacing Main Burners, Crossover Ignition System Operations

Page 31

Maintenance

Replacing Main Burners

1)Your Weber® gas barbecue must be OFF and cool.

2)Turn gas OFF at source.

3)To remove control panel: take off the burner control knobs. Remove the screws holding the control panel in place. Lift off the control panel.

4)Unhook the manifold bracket(1) and unscrew the two wing nuts(2) that hold the manifold to the cooking box. Pull the manifold and valve assembly out of the burners and carefully set it down.

(1)

(2)

5)Slide the burner assembly out from under the guide screw and washer(1) in the corners of the cooking box.

(1)

6)Lift and twist the burner assembly slightly, to separate the crossover tube(1) from the burners. Remove the burners from the cooking box.

(1)

7) To reinstall the burners, reverse 3) through 7).

￿CAUTION: The burner openings(1) must be positioned properly over the valve orifices(2).

Check proper assembly before fastening manifold in place.

(2)

(1)

￿WARNING: After reinstalling the gas lines, they should be leak checked with a soap and water solution before using the barbecue. (See Step: “Check for gas leaks.”)

Crossover® Ignition System Operations

If the Crossover® ignition system fails to ignite the Left burner, light the Left burner with a match. If the Left burner lights with a match, then check the Crossover® ignition system.

Check that both the white(1) and black(2) ignition wires are attached properly.

(1)

(2)

Check that the Crossover® ignition button pushes the igniter (button) down, and returns to the up position.

If the Crossover® ignition system still fails to light, Contact the Customer Service Representative in your region using the contact information sheet provided with your manual.

E-2

Image 31
Contents LP Gas Grill Owner’s Guide N E S I SLiquid Propane GAS Units only Contents Customer Service Center Roselle Road, Suite Schaumburg, IL WarrantyOperating For Installation in CanadaGeneral Instructions Storage and/or NonuseCooking CleaningExploded View Exploded View List Parts List Unpacking Ba301.a Page Page B302LP.b Page Page Page Page Page Flames in the area while you check for leaks Connecting the Liquid Propane CylinderDo not use an open flame to check for gas Leaks. Be sure there are no sparks or openTo Connect the hose to the cylinder Remove control panel and burner control knobs Check for gas leaksRemoval of the LP cylinder For Canada only Safe handling tips for Liquid Propane GasCylinders Liquid Propane Cylinder requirementsLighting Operating InstructionsTo Extinguish Manual Lighting On a bright sunny day Failure to open the lid while igniting the sideBurner, or not waiting 5 minutes to allow Gas to clear if the side burner does not lightProblem Check Cure TroubleshootingFlame is very yellow Side Burner TroubleshootingConjunction with the smell of gas Weber Spider /Insect screens MaintenanceAnnual Maintenance Main Burner Cleaning ProcedureCrossover Ignition System Operations Replacing Main Burners