Weber 55553 General Instructions, Storage and/or Nonuse, For Installation in Canada, Operating

Page 5

General Instructions

Your Weber® gas barbecue is a portable outdoor cooking appliance. With the Weber® gas barbecue you can grill, barbecue, roast and bake with results that are difficult to duplicate with indoor kitchen appliances. The closed lid and Flavorizer® Bars produce that “outdoor” flavor in the food.

The Weber® gas barbecue is portable so you can easily change its location in your yard or on your patio. Portability means you can take your Weber® gas barbecue with, if you move.

Liquid Propane (LP) gas supply is easy to use and gives you more cooking control than charcoal fuel.

These instructions will give you the minimum require- ments for assembling your Weber® gas barbecue. Please read the instructions carefully before using your Weber® gas barbecue. Improper assembly can be dangerous.

Not for use by children.

If there are local codes that apply to portable gas grills, you will have to conform to them. If there are no local codes, you must conform to the latest edition of the National Fuel Gas Code: ANSI Z 223.1/NFPA54.

The pressure regulator supplied with the Weber® gas barbecue must be used. This regulator is set for 10.5 inches of water column (pressure).

This Weber® gas barbecue is designed for use with liquid propane (LP) gas only. Do not use with natural (piped in city) gas. The valves, orifices, hose and regulator are for LP gas only.

Do not use with charcoal fuel.

Check that the area under the control panel and the bottom tray are free from debris that might obstruct the flow of combustion or ventilation air.

The areas around the LP cylinder must be free and clear from debris.

For Installation in Canada

These instructions, while generally acceptable, do not necessarily comply with the Canadian Installation codes, particularly with piping above and below ground. In Canada the installation of this appliance must comply with local codes and/or Standard CAN/CGA-B149.2 (Installa- tion Code for Propane Burning Appliances and Equip- ment).

Storage and/or Nonuse

The gas must be turned off at the liquid propane cylinder when the Weber® gas barbecue is not in use.

When the Weber® gas barbecue is stored indoors, the gas supply must be DISCONNECTED and the LP cylinder stored outdoors in a well-ventilated space.

LP cylinder must be stored outdoors in a well -ventilated area out of reach of children. Disconnected LP cylinder must not be stored in a building, garage or any other enclosed area.

When the LP cylinder is not disconnected from the Weber® gas barbecue, the appliance and LP tank must be kept outdoors in a well-ventilated space.

The Weber® gas barbecue should be checked for gas leaks and any obstructions in the burner tubes before using. (See Sections: “General Maintenance and Annual Maintenance.”)

Check that the areas under the control panel and the slide out bottom tray are free from debris that might obstruct the flow of combustion or ventilation air.

The Spider /Insect Screens should also be checked for any obstructions. (See Section: “Annual Maintenance.”)

Operating

WARNING: Only use this barbecue outdoors in a well-ventilated area. Do not use in a garage, build- ing, breezeway or any other enclosed area. WARNING: Your Weber® gas barbecue shall not be used under an unprotected combustible roof or overhang.

WARNING: Your Weber® gas barbecue is not in- tended to be installed in or on recreational vehicles and/or boats.

WARNING: Do not use the barbecue within 24 inches of combustible materials, top, bottom, back or sides of the grill.

WARNING: The entire cooking box gets hot when in use. Do not leave unattended.

WARNING: Keep any electrical supply cord and the fuel supply hose away from any heated surface. WARNING: Keep the cooking area clear of flam- mable vapors and liquids such as gasoline, alcohol, etc., and combustible materials.

WARNING: Never store an extra (spare) LP cylinder under or near the Weber® gas barbecue.

A-5

Image 5
Contents LP Gas Grill Owner’s Guide N E S I SLiquid Propane GAS Units only Contents Customer Service Center Roselle Road, Suite Schaumburg, IL WarrantyGeneral Instructions For Installation in CanadaStorage and/or Nonuse OperatingCooking CleaningExploded View Exploded View List Parts List Unpacking Ba301.a Page Page B302LP.b Page Page Page Page Page Do not use an open flame to check for gas Connecting the Liquid Propane CylinderLeaks. Be sure there are no sparks or open Flames in the area while you check for leaksTo Connect the hose to the cylinder Remove control panel and burner control knobs Check for gas leaksRemoval of the LP cylinder Cylinders Safe handling tips for Liquid Propane GasLiquid Propane Cylinder requirements For Canada onlyTo Extinguish Operating InstructionsLighting Manual Lighting Burner, or not waiting 5 minutes to allow Failure to open the lid while igniting the sideGas to clear if the side burner does not light On a bright sunny dayProblem Check Cure TroubleshootingConjunction with the smell of gas Side Burner TroubleshootingFlame is very yellow Annual Maintenance MaintenanceMain Burner Cleaning Procedure Weber Spider /Insect screensCrossover Ignition System Operations Replacing Main Burners