Weber 2000 Series General Maintenance, Weber Spider Stopper Guards, Main Burner Flame Pattern

Page 29

General Maintenance

Weber Spider Stopper Guards

Your Weber Gas Barbecue, as well as any outdoor gas appliance, is a target for spiders and other insects. They can nest in the venturi section of the burner tubes. This blocks the normal gas flow, and can cause the gas to flow back out of the air shutter. Figure 9. This could result in a fire in and around the air shutters, under the control panel, causing serious damage to your barbecue.

Venturi

Main Burner Flame Pattern

The Weber Gas Barbecue burners have been factory set for the correct air and gas mixture. The correct flame pattern is shown in Figure 11.

Burner inside

Tips occasionally yellowish

cooking box

 

Light blue

Dark blue

Flames

Air shutter

Venturi fin

Figure 11

Figure 9

The Weber Spider Stopper Guard is factory installed. It fits tightly around the air shutter section of the burner tube and the valve, thereby preventing spiders and other insects access to the burner tubes through the air shutter openings. Figure 10.

If the flames do not appear to be uniform the length of the burner tube, follow the burner cleaning procedures.

Main Burner Cleaning Procedure(See Section

“Replacing the main burners”.)

Look inside each burner with a flashlight. Figure 12.

Weber Spider

Stopper Guard

Figure 10

We recommend that you inspect the Weber Spider Stopper Guards at least once a year. (See section “Annual Maintenance”.) Also inspect and clean the Spider Stopper Guards if any of the following symptoms should ever occur.

1.The smell of gas in conjunction with the burner flames appearing yellow and lazy.

2.Barbecue does not reach temperature.

3.Barbecue heats unevenly.

4.One or more of the burners do not ignite.

mDANGER

Failure to correct these symptoms may result in a fire which can cause serious bodily injury or death and cause damage to property.

Figure 12

Clean the inside of the burners with a wire (a straightened out coat hanger will work). Figure 13. Check and clean the air shutter opening at the ends of the burners. Check and clean the valve orifices at the base of the valves. Use a brass bristle brush to clean outside of burners. This is to make sure all the burner ports are fully open.

Figure 13

mCAUTION: Do not enlarge the burner ports when cleaning.

Replacing Main Burners

a)Your Weber Gas Barbecue must be OFF and cool.

b)Turn gas OFF at source.

c)Remove control panel: take off the burner control knobs. Remove the screws holding the control panel in place. Lift off the control panel.

29

Image 29
Contents Genesis 2000 Series LP GAS Units only MDANGER MWARNINGSWarranty Patents and Trademarks Contents General Instructions For Installation in CanadaStorage Operating areaStep AssemblyCheck package contents BER E W REB Check contents of hardware packs Assemble frame Assemble wheelsInsert casters Continue frame assemblyComplete frame assembly Add cooking box Install tank panel assembly Install manifold bracketAdd fuel scale Install igniterFill LP tank Set LP fuel scaleConnect LP tank Check that the burner valves are offCheck for gas leaks Install the bottom tray Install Flavorizer Bars and Cooking GratesInstall tool holders, control panel and burner control knobs Install the lidInstall swing table Complete accessory installation To Extinguish LightingManual Lighting Cooking Periodic CleaningStorage and/or Nonuse Storage and/or NonuseRefilling the LP tank Connecting the filled LP tankMale fitting Regulator DOT 4BA240 Safe handling tips for LP GasInspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceMain Burner Cleaning ProcedureSee Section General MaintenanceWeber Spider Stopper Guards Main Burner Flame PatternTo reinstall burners, reverse steps c through g Crossover Ignition System Operations Troubleshooting Page 10-11 Parts List Final Word of Thanks