Weber Platinum B manual Crossover Ignition System Operations

Page 23

9)Reinstall the Spider Stopper Guards. Slightly rotate the Spider Stopper Guards so that the seams are in line with the Venturi fins(1). There should be no gaps in the seams or in the fit around the burners(2) and valves(3).

(1)

(3)

(2)

CAUTION: If the Spider Stopper Guards do not fit tightly, contact the Customer Service Representative in your region using the contact information sheet provided with your manual.

WARNING: After reinstalling the gas lines, they should be leak checked with a soap and water solution before using the barbecue. (See Step: “Check for gas leaks.”)

Crossover® Ignition System Operations

If the Crossover Ignition System fails to ignite the Left burner, light the Left burner with a match. If the Left burner lights with a match, then check the Crossover Ignition System.

Check that both the white(1) and black(2) ignition wires are attached properly.

(1)

(2)

Check that the Crossover Ignition button pushes the igniter (button) down, and returns to the up position.

Check to see if the igniter is loose in the frame. Tighten if necessary; See Step “Install igniter” for correct procedure.

If the Crossover Ignition System still fails to light, Contact the Customer Service Representative in your region using the contact information sheet provided with your manual.

D-7

Image 23
Contents Genesis PLATINUM-B Liquid Propane GAS Units only Palatine, IL Customer Service CenterSouth Hicks Road Contents Operating Gas Supply TestingFor Installation in Canada StorageGenesis Platinum-B NG Manifold, Hose and regulator assembled Page Packaging requires at least two people Page Catch pan Cooking box with finger grip toward you1Num foil. It can cause grease fires by trapping Grease and not allowing grease to flow intoInstall the bottom shelf Installing the warming rackInstalling Smoker Box Check that all burner valves are off Frame1. Slip washers on the bolts and insert the boltsAs shown2. Tighten For leaks. Sparks or open flames will Do not use an open flame to check forGas leaks. Be sure there are no sparks or Open flames in the area while you checkPage You will need right work surface, two 1/2 inch bolts To Extinguish LightingManual Lighting Storage CleaningCooking Inspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceWeber Spider Stopper Guards General MaintenanceMain Burner Cleaning Procedure Replacing Main Burners Crossover Ignition System Operations Smell of gas Flame is low when burner is onBurners burn with a yellow or Orange flame, in conjunction with