Weber 3100 Annual Maintenance, Inspection and Cleaning of the Weber Spider Stopper Guards

Page 27

Annual Maintenance

After a period of nonuse we recommend that you perform the following maintenance procedures for your safety.

mWARNING: Check hose before each use of barbecue for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the barbecue. Replace using only Weber authorized replacement hose. Order from Weber-Stephen Products Co., Customer Service Center or authorized dealer.

Inspect the burners for correct flame pattern. Clean if necessary, following the procedures outlined in the "General Maintenance" section of this manual.

Check all gas fittings for leaks.

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or death, and damage to property.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

You will need: a soap and water solution and a rag or brush to apply it.

Make sure main burners are in the OFF position.

Make sure side burner is OFF. Remove valve control knob and screws. Remove enamel top.

To perform leak checks: Turn on gas supply.

mWARNING: Do not ignite burners while leak checking.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows there is a leak.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

Check:

a)Hose to manifold connection. Figure 5 (a).

b)Manifold to side burner hose connection. Figure 5 (b).

mWARNING: If there is a leak at connection a, retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact

Weber-Stephen Customer Service.

c)Side burner hose to side burner connection. Figure 5 (c).

d)Valves to manifold connections. Figure 5 (d).

e)Hose to quick disconnect connection. Figure 5 (e).

mWARNING: If there is a leak at connections

(b), (c), (d) or (e), turn OFF the gas. DO NOT OPERATE

THE BARBECUE. Contact Weber-Stephen Customer Service.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

(a)(b)

(c)

(d)

Figure 5

(e)

Inspection and Cleaning of the Weber Spider Stopper Guards

To inspect the Spider Stopper Guards, remove the control panel and look to see if they have dust or dirt on their outside surfaces. If they do, brush off the outside surface of the Spider Stopper Guards with a soft bristle brush (an old toothbrush for example). Check that there are no gaps in the Spider Stopper Guards’ seams or in the fit around the burners or valves. (See Section "General Maintenance".)

27

Image 27
Contents Genesis 3100 Series LP GAS Units only MDANGER MWARNINGSWarranty Patents and Trademarks Contents Storage For Installation in CanadaGas supply testing General InstructionsAssembly Check package contentsStep BER E W REB Check contents of hardware packs Assemble frame Assemble wheelsContinue frame assembly Complete frame assemblyInsert casters Add cooking box Install side burner locksTest connections Install gas supplyGeneral Specifications for Piping Gas line pipingConnect flexible hose to manifold Install igniter Check that all burner valves are offInstall side burner Install manifold bracketMWARNING Make sure gas supply is OFF Check for gas leaks Death and damage to propertyMWARNING Do not ignite burners while leak checking Install Flavorizer Bars and Cooking Grates Install the lid Install the bottom trayMCAUTION Make sure both locks have snapped into place Secure side burnerInstall swing table Complete accessory installation Lighting To ExtinguishTurn gas supply OFF at the source, then push down Manual Lighting Lighting only the side burner. Figure Lighting the side burnerDrippings and grease Periodic CleaningCooking Storage and/or NonuseCast Iron Cooking Grates Inspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceMain Burner Flame Pattern General MaintenanceMain Burner Cleaning Procedure Weber Spider Stopper GuardsView from behind cooking box Wing nuts Crossover Ignition System Operations Burner flame pattern is erratic. Flame is low Burner does not light, or flame is low in High positionSide Burner Maintenance Side Burner TroubleshootingPage Use only Weber factory authorized parts. Parts List13,18 Final Word Thanks