Weber 3100 owner manual Check for gas leaks, Death and damage to property

Page 16

Step 15

Check for gas leaks

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or

To perform leak checks: Slide back the collar of the quick disconnect. Push male fitting of the hose into the quick disconnect, and maintain pressure. Figure 17 (a). Slide the collar closed. Figure 17 (b). If it does not engage or lock, repeat procedure. Gas will not flow unless the quick disconnect is properly engaged.

Turn on gas supply.

Locking shut off

death and damage to property.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

Note - All factory made connections have been thoroughly checked for gas leaks. The burners have been flame tested. As a safety precaution you should recheck all fittings for leaks before using your Weber Gas Barbecue. Shipping and handling may have loosened or damaged a

To barbecue

(a)

 

Male fitting

(b)

Outside house wall

Collar

gas fitting.

mWARNING: Perform these leak checks even if your barbecue was dealer or store assembled.

You will need: a soap and water solution and a rag or brush to apply it.

Note - Since some leaks test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

Make sure side burner is OFF. Remove valve control knob and screws. Remove porcelain top. Figure 16.

Figure 16

Quick disconnect engaged

Figure 17

mWARNING: Do not ignite burners while leak checking.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows there is a leak.

16

Image 16 Contents
Genesis 3100 Series MDANGER MWARNINGS LP GAS Units onlyWarranty Patents and Trademarks Contents For Installation in Canada Gas supply testingGeneral Instructions StorageCheck package contents AssemblyStep BER E W REB Check contents of hardware packs Assemble wheels Assemble frameComplete frame assembly Continue frame assemblyInsert casters Install side burner locks Add cooking box Install gas supply General Specifications for Piping Gas line piping Test connectionsInstall igniter Check that all burner valves are off Connect flexible hose to manifoldInstall manifold bracket Install side burnerMWARNING Make sure gas supply is OFF Death and damage to property Check for gas leaksMWARNING Do not ignite burners while leak checking Install Flavorizer Bars and Cooking Grates Install the bottom tray Install the lidSecure side burner MCAUTION Make sure both locks have snapped into placeInstall swing table Complete accessory installation To Extinguish LightingTurn gas supply OFF at the source, then push down Manual Lighting Lighting the side burner Lighting only the side burner. FigurePeriodic Cleaning CookingStorage and/or Nonuse Drippings and greaseCast Iron Cooking Grates Annual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsGeneral Maintenance Main Burner Cleaning ProcedureWeber Spider Stopper Guards Main Burner Flame PatternView from behind cooking box Wing nuts Crossover Ignition System Operations Burner does not light, or flame is low in High position Burner flame pattern is erratic. Flame is lowSide Burner Troubleshooting Side Burner MaintenancePage Parts List Use only Weber factory authorized parts.13,18 Final Word Thanks