Weber 38008 manual Lighting the Smoker Burner

Page 20

20

OPERATING INSTRUCTIONS

 

 

LIGHTING THE SMOKER BURNER

WARNING: Check hose before each use of grill for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the grill. Replace using only Weber® authorized replacement hose. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

1)Open the grill lid.

DANGER:

Failure to open the lid while igniting the grill, or not waiting 5 minutes to allow the gas to clear if the grill does not light, may result in an explosive flare-up which can cause serious bodily injury or death.

2)Open smoker box lid

3)Fill smoker with water soaked wood chunks or chips.

4)Make sure all burner control knobs are turned OFF. (Push control knob down and turn clockwise to ensure that it is in the OFF position.)

WARNING: The burner control knobs must be in the OFF position before turning on the liquid propane cylinder tank valve. If they are not in the OFF position, when you turn on the LP cylinder valve, the "excess gas flow control" feature will activate, limiting the flow of gas from the LP cylinder. If this should occur, turn OFF the LP cylinder valve and burner control knobs. Then start over.

DANGER:

When the "excess gas flow control" feature is activated, a small amount of gas is still flowing to the burners. After turning OFF the cylinder and burner control knobs, wait at least 5 minutes for the gas to clear before attempting to light the grill. Failure to do so may result in an explosive flare-up, which can cause serious bodily injury or death.

SUMMIT® C, D

1

2,3,9

8 6

4

 

7

5

 

4

*The grill illustrated may have slight differences than the model purchased.

Image 20
Contents Summit GAS Grill LP US EnglishLiquid Propane GAS Units only For replacement parts call WarrantyCustomer Service Center Roselle Road, Suite Schaumburg, IL For Installation in Canada General InstructionsStorage AND/OR Nonuse OperatingGrilling Methods Cleaning Connecting the Liquid Propane Cylinder Important LP Cylinder InformationCheck That ALL Burner Valves are OFF To Connect the hose to the cylinderGAS Instructions Check for GAS Leaks Remove Control PanelCheck for GAS Leaks Summit a Reinstall Control Panel Gold B4Refilling the Liquid Propane Cylinder Checking the Fuel Level in Your TankSafe Handling Tips for Liquid Propane GAS Cylinders Removal of the LP cylinderCanada Liquid Propane Cylinder requirements Liquid Propane LP CylindersLiquid Propane Cylinder requirements Flavorizer system Grilling MethodsDirect Cooking Grilling Tips & Helpful Hints Operating InstructionsIndirect Cooking Lighting Crossover Ignition SystemTo Extinguish Manual Lighting Operating Instructions Lighting the side burner if the main burners are lit Side Burner Lighting InstructionsLighting only the side burner To use the smoker Using the SmokerCleaning the smoker Lighting the Smoker Burner Manually Lighting the Smoker Burner Operating Instructions Rotisserie Assembly Install the motor bracketAttach the motor Put the spit forks on the rotisserie shaftUsing the Rotisserie Important Safeguards CookingLighting the Rotisserie Burner Lighting Rotisserie BurnerTo Extinguish Manually Lighting the Rotisserie Burner Operating Instructions Main and Smoker Troubleshooting Side Burner Troubleshooting Side Burner MaintenanceRotisserie Troubleshooting Maintenance Annual MaintenanceInspection and cleaning of the Spider/Insect screens Weber Spider /INSECT ScreensMain Burner Cleaning Procedure Main Burner Flame PatternReplace Main Burners Turn off the gas supplyMaintenance Maintenance Crossover Ignition System Operations Replace Igniter Batteries