Weber 42373 manual Manual Lighting

Page 10

OPERATING INSTRUCTIONS

Manual Lighting

DANGER

Failure to open lid while igniting the barbecue's burners, or not waiting 5 minutes to allow the gas to clear if the barbecue does not light, may result in an explosive flame-up which can cause serious bodily injury or death.

1)Open the lid.

2)Make sure all burner control knobs are turned OFF. (Push each burner control knob down and turn clockwise to ensure they are in the off position.)

3)Turn the gas supply valve on.

4)Put match in the match holder and strike match.

WARNING: Do not lean over open barbecue.

5)Push LEFT burner control knob down and turn to START/HI.

6)Insert match holder and lit match down through cooking grates and Flavorizor® bars to ignite LEFT burner in each selected burner set.

WARNING: If the burner does not light, turn the LEFT burner control knob to OFF and wait 5 minutes to let the gas clear before you try again.

7)After LEFT burner is lit you can turn on the RIGHT burner adjacent to it. The RIGHT burner lights from the LEFT burner.

1

4,5,7

6

2

3

2

*The grill illustrated may have slight differences than the model purchased.

To Extinguish

Push down and turn each burner control knob clock- wise to the OFF position. Turn gas supply OFF at the source.

10

Image 10
Contents BUILT-IN Natural GAS Grill Owners Guide 42373 US 04/01/04 NG US EnglishLiquid Propane GAS Units only Storage WarrantyWarranty OperatingGeneral Instructions Gas Supply TestingCleaning Grilling MethodsCheck for gas leaks GAS InstructionsRemove control panel Reinstall control panel Operating Instructions Flavorizer systemGrilling Tips & Helpful Hints Indirect cookingLighting To ExtinguishManual Lighting Main Burner Troubleshooting Problem Check CureMain Burner Cleaning Procedure MaintenanceAnnual Maintenance Weber Spider /INSECT ScreensReplacing Main Burners Check proper assembly before fastening manifold in place Valve orificesCrossover Ignition System Operations Replace Igniter Batteries