Install gas supply

General Specifications for Piping

Note - Contact your local municipality for building codes regulating outdoor gas barbecue installations. In absence of Local Codes, you must conform to the latest edition of ANSI Z223.1. WE RECOMMEND THAT THIS INSTALLATION BE DONE BY A PROFESSIONAL.

Some of the following are general requirements taken from ANSI Z223.1, for gas supply installations. Refer to ANSI Z223.1 latest edition for complete specifications.

This barbecue is designed to operate at 7 inches of water column pressure (.2526 psi).

A manual shut-off valve must be installed outdoors, immediately ahead of the quick disconnect.

An additional manual shut-off valve indoors should be installed in the branch fuel line in an accessible location near the supply line.

The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The quick disconnect fitting is a hand-operated device that automatically shuts OFF the flow of gas from the source when the barbecue is disconnected.

The quick disconnect fitting can be installed horizontally, or pointing downward. Installing the fitting with the open end pointing upward can result in collecting water and debris.

The dust covers (supplied plastic plugs) help keep the open ends of the quick disconnect fitting clean while disconnected.

Pipe compound should be used which is resistant to the action of natural gas when connections are made.

The outdoor connector must be firmly attached to rigid, permanent construction.

mWARNING: Do not route the 12 foot hose under a deck. The hose must be visible.

Typical natural gas supply installation. Figure 12.

Gas supply

Inside wall

Outside wall

Shut off

To barbecue

Quick Disconnect

Locking

shut off

 

Male fitting

 

Figure 12

The quick disconnect is

 

installed above ground

Gas line piping

If the length of line required does not exceed 50 feet, use a 5/8" O.D. tube. One size larger should be used for lengths greater than 50 feet.

Gas piping may be copper tubing, type K or L; polyethylene plastic tube, with a minimum wall thickness of .062 inch; or standard weight (schedule 40) steel or wrought iron pipe.

Copper tubing must be tin-lined if the gas contains more than 0.3 grams of hydrogen sulfide per 100 cubic feet of gas.

Plastic tubing is suitable only for outdoor, underground use.

Gas piping in contact with earth, or any other material which may corrode the piping, must be protected against corrosion in an approved manner.

Underground piping must have a minimum of 18" cover.

Test connections

All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of ANSI Z223.1.

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for gas leaks. This will result in a fire or explosion which can cause serious bodily injury or death, and damage to property.

15

Image 15
Contents Genesis 1000 LX LP GAS Units only MDANGER MWARNINGSWarranty Patents and Trademarks Contents Storage For Installation in CanadaGas supply testing General InstructionsAssembly Check package contentsStep Two wheels Check contents of hardware packs Assemble frame Assemble wheelsComplete frame assembly Continue frame assemblyAdd front panel Insert castersAdd cooking box Install igniter Install manifold bracketTest connections Install gas supplyGeneral Specifications for Piping Gas line pipingConnect flexible hose to manifold Check that all burner valves are offCheck for gas leaks Install the bottom tray Install Flavorizer Bars and Cooking GratesAdd tool holders, control panel and burner control knobs Install LidInstall swing table Complete accessory installation To Extinguish LightingManual Lighting Periodic Cleaning CookingStorage and/or Nonuse Inspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceReplacing Main Burners General MaintenanceWeber Spider Stopper Guards Main Burner Flame PatternTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations Troubleshooting 14-15 52-55 10,14 19-20 Parts List Final Word Thanks