Weber 1200 owner manual Check that all burner valves are off, Connect LP tank

Page 17

Step 15

Check that all burner valves are off

You will need: one burner control knob.

Valves are shipped in the OFF position, but you should check to be sure. Put the knob on each valve. Check by pushing down and turning clockwise. If they do not turn, they are off, proceed to the next step. Figure 16.

Figure 16

The hose and regulator are connected in the following manner:

Slide back the collar of the quick disconnect on the tank valve. Push the male fitting of the regulator into the quick disconnect, and maintain pressure. Slide the collar closed. Figure 18 (a). Figure 18 (b) shows the quick disconnect engaged and various components of the tank and regulator. Regulator vent hole should be at 3, 6, or 9 o'clock. It should not be pointed up. Figure 18 (c).

(a)

Collar

Male fitting

Step 16

Connect LP tank

mWARNING: Make sure that the LP tank valve is closed. Close by turning clockwise.

Hook the LP tank onto the fuel scale. Loosen the tank lock wing nut. Swing the tank lock down. Tighten the wing nut. Figure 17.

Tank lock

Hose(b)

Tank valve

Regulator

Regulator vent

Valve handwheel close clockwise

Pressure relief valve

Tank

E

wing nut

F

Figure 17

Quick disconnect engaged

(c)

Turn so regulator vent does not collect water

Figure 18

17

Image 17
Contents Platinum 1200 Series LP GAS Units only Warranty Patents and Trademarks Contents General Instructions For Installation in CanadaStorage Operating areaStep AssemblyCheck package contents Warming rack Fuel scale assembly Warm-Up Basket Two casters Check contents of hardware packs Assemble top frame Assemble wheelsComplete frame assembly Continue frame assemblyAdd front panel Insert castersAdd cooking box Install tank panel assembly Install manifold bracketInstall igniter Add fuel scale assemblyFill LP tank MCAUTION Do not remove adjustment wing nut from tank scaleSet LP fuel scale Connect LP tank Check that all burner valves are offCheck for gas leaks MWARNING Do not ignite burners when leak checkingInstall the bottom tray Install Flavorizer Bars and Cooking GratesAdd tool holders, control panel and burner control knobs Install LidInstall swing table Complete accessory installation To Extinguish LightingManual Lighting Cooking Periodic CleaningStorage and/or Nonuse Storage and/or NonuseRemoval of the LP tank Connecting the filled LP tankRefilling the LP tank Engaged Liquid Propane LP Tanks Safe handling tips for LP GasMWARNING Do not ignite burners while leak checking Annual MaintenanceInspection and Cleaning of the Weber Spider Stopper Guards MCAUTION Do not enlarge the burner ports when cleaning General MaintenanceWeber Spider Stopper Guards Main Burner Flame PatternTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations Burner does not light, or flame is low in High position When burner is on HIGH. Flames do not runMCAUTION Do not line the bottom tray with aluminum foil Burner flame pattern is erratic. Flame is low14-15 19-20,15 10,15 Parts List Final Word Thanks