Step 15
Check that all burner valves are off
You will need: one burner control knob.
Valves are shipped in the OFF position, but you should check to be sure. Put the knob on each valve. Check by pushing down and turning clockwise. If they do not turn, they are off, proceed to the next step. Figure 16.
Figure 16
The hose and regulator are connected in the following manner:
Slide back the collar of the quick disconnect on the tank valve. Push the male fitting of the regulator into the quick disconnect, and maintain pressure. Slide the collar closed. Figure 18 (a). Figure 18 (b) shows the quick disconnect engaged and various components of the tank and regulator. Regulator vent hole should be at 3, 6, or 9 o'clock. It should not be pointed up. Figure 18 (c).
(a)
Collar
Male fitting
Step 16
Connect LP tank
mWARNING: Make sure that the LP tank valve is closed. Close by turning clockwise.
Hook the LP tank onto the fuel scale. Loosen the tank lock wing nut. Swing the tank lock down. Tighten the wing nut. Figure 17.
Tank lock |
Hose(b)
Tank valve
Regulator
Regulator vent
Valve handwheel close clockwise
Pressure relief valve
Tank
E |
wing nut |
F |
Figure 17
Quick disconnect engaged
(c)
Turn so regulator vent does not collect water
Figure 18
17