Weber 1200 Refilling the LP tank, Connecting the filled LP tank, Removal of the LP tank

Page 26

Refilling the LP tank

We recommend that you refill before the scale indicator reaches "E".

Note - If you run out of fuel, check the indicator setting and/or adjust the fuel scale indicator setting with the scale setting wing nut while the tank is empty so you do not run out again.

Removal of the LP tank

1)Close tank valve (turn clockwise). Figure 3 (a).

2)Slide the collar back on the quick disconnect to disengage the fitting. Figure 3 (b).

3)Loosen tank lock wing nut and turn tank lock up out of the way.

4)Lift tank off.

To refill take LP tank and tank filler adapter to a "Gas Propane" dealer.

mWARNING: We recommend that your LP tank be filled at an authorized LP gas dealer, by a qualified attendant, who fills the tank by weight. IMPROPER FILLING IS DANGEROUS.

mWARNING: If you exchange your LP tank, make sure you get a similar tank in return. Your LP tank is equipped with a quick-disconnect valve and an OPD (Overfilling Prevention Device). Other LP tanks are not compatible with your barbecue connection.

Scale setting wing nut

Tank lock

wing nut

(a)

Tank valve

Collar

(b)

Connecting the filled LP tank

mWARNING: Make sure that the LP tank valve is closed. Close by turning clockwise.

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

You will need: LP tank, a soap and water solution and a rag or brush to apply it.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks

a)Lift and hook the tank onto the fuel scale.

b)Loosen the tank lock wing nut. Swing the tank lock down. Tighten the wing nut. Figure 4.

Figure 4

Figure 3

26

Image 26
Contents Platinum 1200 Series LP GAS Units only Warranty Patents and Trademarks Contents Storage For Installation in CanadaGeneral Instructions Operating areaStep AssemblyCheck package contents Warming rack Fuel scale assembly Warm-Up Basket Two casters Check contents of hardware packs Assemble wheels Assemble top frameContinue frame assembly Complete frame assemblyInsert casters Add front panelAdd cooking box Install manifold bracket Install tank panel assemblyAdd fuel scale assembly Install igniterFill LP tank MCAUTION Do not remove adjustment wing nut from tank scaleSet LP fuel scale Check that all burner valves are off Connect LP tankMWARNING Do not ignite burners when leak checking Check for gas leaksInstall Flavorizer Bars and Cooking Grates Install the bottom trayInstall Lid Add tool holders, control panel and burner control knobsInstall swing table Complete accessory installation Lighting To ExtinguishManual Lighting Storage and/or Nonuse Periodic CleaningCooking Storage and/or NonuseRemoval of the LP tank Connecting the filled LP tankRefilling the LP tank Engaged Safe handling tips for LP Gas Liquid Propane LP TanksMWARNING Do not ignite burners while leak checking Annual MaintenanceInspection and Cleaning of the Weber Spider Stopper Guards Weber Spider Stopper Guards General MaintenanceMCAUTION Do not enlarge the burner ports when cleaning Main Burner Flame PatternTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations MCAUTION Do not line the bottom tray with aluminum foil When burner is on HIGH. Flames do not runBurner does not light, or flame is low in High position Burner flame pattern is erratic. Flame is low14-15 19-20,15 10,15 Parts List Final Word Thanks