Brinkmann Series 4435 owner manual PRE-START Check List

Page 10

6.Check each place listed (A– K) for growing bubbles which indicates a leak.

7.Turn off gas supply at cylinder valve.

8.Turn on control knobs to release gas pressure in hose.

9.Turn control knobs to "OFF" position.

10.Tighten any leaking connections.

11.Repeat soapy water test until no leaks are detected.

12.Turn off gas supply at cylinder valve until you are ready to use your grill.

13.Wash off soapy residue with cold water and towel dry.

14.Wait 5 minutes to allow all gas to evacuate the area before lighting grill.

CAUTION! DO NOT use the grill if leaks cannot be stopped. Contact a qualified gas appliance repair service.

Note: The leak test must be performed in an area that has adequate lighting in order to see if bubbles are developing.

WARNING

PRE-START CHECK LIST:

Property damage, bodily harm, severe burns, and death could result from failure to follow these safety steps. These steps should be performed after the grill has been assembled and prior to each use. DO NOT operate this grill until you have read and understand ALL of the warnings and instructions in this manual.

PRE-START CHECK LIST:

Ensure that the grill is properly assembled.

Inspect the gas supply hose for burns, chaffing, kinks, and proper routing before each use. If it is evident there is excessive abrasion or wear, or the hose is cut, it must be replaced prior the grill being used. Replace with hose and regulator, Model No. 155-4400-0, which can be obtained by contacting customer service at 800-527-0717.

Leak check all gas connections and hose. See section on "Leak Testing".

Ensure that all electrical supply cords are properly grounded. Keep any electrical supply cord and the fuel supply hose away from any heated surfaces. Hose should be at least 3 inches from hot surfaces.

Position your grill on level ground in a well ventilated location, a safe distance from combustible materials, buildings and overhangs.

Properly place the empty grease tray under the grease drain hole in the bottom of the grill to catch grease during use.

DO NOT obstruct the flow of combustion and ventilation air.

9

Image 10
Contents Gas Outdoor Grill Important Safety Table of Contents General Warnings Installation Information LP GAS Cylinder not Supplied with this GrillCylinder Specifications Filling the LP GAS Cylinder Installing the LP GAS Cylinder Onto the GrillRegulator Resetting Procedure Hose and RegulatorConnecting Hose and Regulator to AN LP GAS Cylinder Connecting Hose and RegulatorWhen to Perform a Leak Test Leak TestingChecking for Leaks PRE-START Check List Lighting the Main Burners Lighting InstructionsMatch Lighting the Main Burners Match Lighting the Rotisserie Burner Lighting the Rotisserie BurnerLighting the Side Burner Match Lighting the Side Burner Turning OFF the GrillPreheating the Grill Operating the GrillBreaking in Your Grill Controlling FLARE-UPSRotisserie Cooking Side BurnerGrilling to Proper Temperature CleanlinessHelpful Hints Cleaning and Maintenance Burner ASSEMBLY/MAINTENANCETransporting and Storage Cooking GrillsHeat Distribution Plates Before Storing Your GrillTrouble Shooting Frequently Asked Questions Frequently Asked Questions Assembly Instructions For Missing PARTS, Please Call Customer Service AT Parts BAG Contents Step Tank Tray Assembly Grill Body Assembly Step Attach the door handles using two M4 X 40mm bolts Step Tool Drawer Place side burner grate on side burner Step Step ProSeries 4435 Assembled Warranty

Series 4435 specifications

The Brinkmann Series 4435 is a notable addition to the realm of analytical laboratory instruments, designed primarily for high-performance liquid chromatography (HPLC). Known for its precision, reliability, and user-friendly operation, this series provides essential support in various applications, including drug development, environmental monitoring, and food safety testing.

One of the main features of the Brinkmann Series 4435 is its innovative pump design, which ensures consistent flow rates and pressure stability. This is critical for achieving accurate and reproducible results in chromatographic analyses. The pump's hermetically sealed construction minimizes the risk of sample contamination, making it a preferred choice for sensitive analytical tasks.

Equipped with advanced technology, the Brinkmann Series 4435 utilizes a dual-channel detection system that enhances sensitivity and selectivity. This system allows simultaneous monitoring of multiple analytes, significantly improving throughput in a busy laboratory setting. The integration of state-of-the-art photodiode array (PDA) detectors facilitates the collection of spectral data across a wide wavelength range, providing researchers with comprehensive insights into sample composition.

The instrument's user interface is designed to be intuitive, allowing operators to set up methods and control the instrument effortlessly. The touch screen display provides real-time data visualization, which helps in monitoring the separation process as it occurs. The flexibility of the Brinkmann Series 4435 also extends to its compatibility with various chromatographic columns, enabling users to adapt the system to different applications as needed.

Durability and maintenance ease are additional characteristics that distinguish the Brinkmann Series 4435 from other models. The robust construction ensures long-term operation without frequent breakdowns, while its modular design allows for simple repairs and component replacements.

In summary, the Brinkmann Series 4435 stands out for its high-performance capabilities and advanced technologies, including a reliable pump system, dual-channel detection, and an intuitive user interface. These features make it an ideal instrument for laboratories striving for accuracy, efficiency, and versatility in their analytical processes. Whether for routine analysis or complex research applications, the Brinkmann Series 4435 delivers exceptional performance that meets the demands of modern analytical chemistry.