Brinkmann Series 4435 Filling the LP GAS Cylinder, Installing the LP GAS Cylinder Onto the Grill

Page 7

WARNING

FILLING THE LP GAS CYLINDER:

Allow only qualified LP gas dealers to properly fill or repair your LP gas cylinder.

New tanks should be purged prior to filling; inform LP gas dealer if you are using a new tank.

DO NOT allow the cylinder to be filled beyond 80% capacity. Over-filled tanks can create a dangerous condition. Over-filled tanks can build-up pressure and cause the relief valve to expel propane gas vapors. The vapor is combustible and if it comes in contact with a spark source or flame an explosion causing severe burns, bodily harm, or death could occur.

Always use a protective cylinder cap when grill is not connected to cylinder.

If you exchange a cylinder with a qualified exchange program, be sure the cylinder has a Type 1 valve and an over-filling prevention device (OPD).

INSTALLING THE LP GAS CYLINDER ONTO THE GRILL:

1.Check that the cylinder valve is closed by turning the knob clockwise.

2.Place the cylinder into the tank holder in the bottom of cabinet.

3.Orient the cylinder such that the valve opening faces the side burner, and so that the hose is not kinked or damaged.

4.Fully tighten the cylinder clamp underneath tank holder to secure tank.

5.Attach or detach regulator to the LP gas cylinder only when cylinder is at rest in tank holder.

HOSE AND REGULATOR:

Your grill is equipped with a Type 1 connection device with the following features:

1.The system will not allow gas flow from the cylinder until a positive connection to the valve has been made.

Note: The cylinder valve must be turned off before any connection is made or removed.

2.A thermal device that will shut off the gas flow if the device is subject to temperatures above 240°F to 300°F (115°C to 150°C). If this should happen, remove the entire regulator assembly and dispose of properly. A replacement regulator assembly can be purchased by contacting customer service at 800-527-0717. The cause of the excessive heat should be determined and corrected before using your grill again.

3.A regulator flow limiting device, when activated, restricts the flow of gas to 10 cubic feet per hour. If the flow limiting device is activated, perform Regulator Resetting Procedure.

Tank Holder

Cylinder Clamp

REGULATOR RESETTING PROCEDURE

1.Turn burner control knobs to "OFF”, turn off the cylinder valve and disconnect regulator from LP gas tank. Wait approximately two minutes.

2.Reattach regulator and slowly turn cylinder valve back on. The flow limiting device will now be reset.

6

Image 7
Contents Gas Outdoor Grill Important Safety Table of Contents General Warnings LP GAS Cylinder not Supplied with this Grill Installation InformationCylinder Specifications Hose and Regulator Installing the LP GAS Cylinder Onto the GrillRegulator Resetting Procedure Filling the LP GAS CylinderConnecting Hose and Regulator Connecting Hose and Regulator to AN LP GAS CylinderWhen to Perform a Leak Test Leak TestingChecking for Leaks PRE-START Check List Lighting the Main Burners Lighting InstructionsMatch Lighting the Main Burners Match Lighting the Rotisserie Burner Lighting the Rotisserie BurnerLighting the Side Burner Turning OFF the Grill Match Lighting the Side BurnerControlling FLARE-UPS Operating the GrillBreaking in Your Grill Preheating the GrillSide Burner Rotisserie CookingGrilling to Proper Temperature CleanlinessHelpful Hints Burner ASSEMBLY/MAINTENANCE Cleaning and MaintenanceBefore Storing Your Grill Cooking GrillsHeat Distribution Plates Transporting and StorageTrouble Shooting Frequently Asked Questions Frequently Asked Questions Assembly Instructions For Missing PARTS, Please Call Customer Service AT Parts BAG Contents Step Tank Tray Assembly Grill Body Assembly Step Attach the door handles using two M4 X 40mm bolts Step Tool Drawer Place side burner grate on side burner Step Step ProSeries 4435 Assembled Warranty

Series 4435 specifications

The Brinkmann Series 4435 is a notable addition to the realm of analytical laboratory instruments, designed primarily for high-performance liquid chromatography (HPLC). Known for its precision, reliability, and user-friendly operation, this series provides essential support in various applications, including drug development, environmental monitoring, and food safety testing.

One of the main features of the Brinkmann Series 4435 is its innovative pump design, which ensures consistent flow rates and pressure stability. This is critical for achieving accurate and reproducible results in chromatographic analyses. The pump's hermetically sealed construction minimizes the risk of sample contamination, making it a preferred choice for sensitive analytical tasks.

Equipped with advanced technology, the Brinkmann Series 4435 utilizes a dual-channel detection system that enhances sensitivity and selectivity. This system allows simultaneous monitoring of multiple analytes, significantly improving throughput in a busy laboratory setting. The integration of state-of-the-art photodiode array (PDA) detectors facilitates the collection of spectral data across a wide wavelength range, providing researchers with comprehensive insights into sample composition.

The instrument's user interface is designed to be intuitive, allowing operators to set up methods and control the instrument effortlessly. The touch screen display provides real-time data visualization, which helps in monitoring the separation process as it occurs. The flexibility of the Brinkmann Series 4435 also extends to its compatibility with various chromatographic columns, enabling users to adapt the system to different applications as needed.

Durability and maintenance ease are additional characteristics that distinguish the Brinkmann Series 4435 from other models. The robust construction ensures long-term operation without frequent breakdowns, while its modular design allows for simple repairs and component replacements.

In summary, the Brinkmann Series 4435 stands out for its high-performance capabilities and advanced technologies, including a reliable pump system, dual-channel detection, and an intuitive user interface. These features make it an ideal instrument for laboratories striving for accuracy, efficiency, and versatility in their analytical processes. Whether for routine analysis or complex research applications, the Brinkmann Series 4435 delivers exceptional performance that meets the demands of modern analytical chemistry.