Brinkmann Series 4435 owner manual Leak Testing, When to Perform a Leak Test, Checking for Leaks

Page 9

DANGER

LEAK TESTING:

To prevent fire or explosion hazard:

DO NOT smoke or permit ignition sources in the area while conducting a leak test.

Perform test OUTDOORS only in a well ventilated area.

Never perform a leak test with a match or open flame.

Never perform a leak test while the grill is in use or while grill is still hot.

WARNING

WHEN TO PERFORM A LEAK TEST:

After assembling your grill and before lighting for the first time, even if purchased fully assembled.

Every time the LP gas cylinder is refilled or if any of the gas components are replaced.

Any time your grill has been moved.

At least once per year or if your grill has not been used for more than 60 days.

CHECKING FOR LEAKS:

1. Create a mixture of 50% water and 50% liquid dishwashing soap.

2. Open the lid.

3. Ensure all control knobs are set to the "OFF" position.

4. Turn on the fuel supply at the cylinder valve. Turn the cylinder valve knob one turn counter-clockwise.

5. Apply the soap water mixture to the following:

Watch For Bubbles

A

Supply tank (cylinder) weld.

I

F

 

G

B

Connection nut to tank valve.

 

H

C

Back side of connection nut to brass

 

 

 

 

nipple.

 

 

D

Brass nipple connection into regulator.

 

 

E

Regulator connections to gas supply hoses.

 

 

F

Gas supply hose connection to side burner valve assembly.

E

J

 

 

G

Side burner valve stem cap.

 

 

H

Side burner connection to hose.

K

 

I

Hose connection to gas manifold.

 

D

J

The full length of gas supply hose.

 

C

K

Tank valve to cylinder.

 

B

 

 

 

A

8

Image 9
Contents Gas Outdoor Grill Important Safety Table of Contents General Warnings LP GAS Cylinder not Supplied with this Grill Installation InformationCylinder Specifications Regulator Resetting Procedure Installing the LP GAS Cylinder Onto the GrillFilling the LP GAS Cylinder Hose and RegulatorConnecting Hose and Regulator Connecting Hose and Regulator to AN LP GAS CylinderLeak Testing When to Perform a Leak TestChecking for Leaks PRE-START Check List Lighting Instructions Lighting the Main BurnersMatch Lighting the Main Burners Lighting the Rotisserie Burner Match Lighting the Rotisserie BurnerLighting the Side Burner Turning OFF the Grill Match Lighting the Side BurnerBreaking in Your Grill Operating the GrillPreheating the Grill Controlling FLARE-UPSSide Burner Rotisserie CookingCleanliness Grilling to Proper TemperatureHelpful Hints Burner ASSEMBLY/MAINTENANCE Cleaning and MaintenanceHeat Distribution Plates Cooking GrillsTransporting and Storage Before Storing Your GrillTrouble Shooting Frequently Asked Questions Frequently Asked Questions Assembly Instructions For Missing PARTS, Please Call Customer Service AT Parts BAG Contents Step Tank Tray Assembly Grill Body Assembly Step Attach the door handles using two M4 X 40mm bolts Step Tool Drawer Place side burner grate on side burner Step Step ProSeries 4435 Assembled Warranty

Series 4435 specifications

The Brinkmann Series 4435 is a notable addition to the realm of analytical laboratory instruments, designed primarily for high-performance liquid chromatography (HPLC). Known for its precision, reliability, and user-friendly operation, this series provides essential support in various applications, including drug development, environmental monitoring, and food safety testing.

One of the main features of the Brinkmann Series 4435 is its innovative pump design, which ensures consistent flow rates and pressure stability. This is critical for achieving accurate and reproducible results in chromatographic analyses. The pump's hermetically sealed construction minimizes the risk of sample contamination, making it a preferred choice for sensitive analytical tasks.

Equipped with advanced technology, the Brinkmann Series 4435 utilizes a dual-channel detection system that enhances sensitivity and selectivity. This system allows simultaneous monitoring of multiple analytes, significantly improving throughput in a busy laboratory setting. The integration of state-of-the-art photodiode array (PDA) detectors facilitates the collection of spectral data across a wide wavelength range, providing researchers with comprehensive insights into sample composition.

The instrument's user interface is designed to be intuitive, allowing operators to set up methods and control the instrument effortlessly. The touch screen display provides real-time data visualization, which helps in monitoring the separation process as it occurs. The flexibility of the Brinkmann Series 4435 also extends to its compatibility with various chromatographic columns, enabling users to adapt the system to different applications as needed.

Durability and maintenance ease are additional characteristics that distinguish the Brinkmann Series 4435 from other models. The robust construction ensures long-term operation without frequent breakdowns, while its modular design allows for simple repairs and component replacements.

In summary, the Brinkmann Series 4435 stands out for its high-performance capabilities and advanced technologies, including a reliable pump system, dual-channel detection, and an intuitive user interface. These features make it an ideal instrument for laboratories striving for accuracy, efficiency, and versatility in their analytical processes. Whether for routine analysis or complex research applications, the Brinkmann Series 4435 delivers exceptional performance that meets the demands of modern analytical chemistry.