Teledyne MX300-I manual Features, Options

Page 11

Portable Oxygen Monitor

Introduction

 

 

 

1.2 Features

The MX300-I is a compact, versatile instrument capable of rapidly measuring the oxygen content of an atmosphere or environment accurately to ±2% over the range 0-100% oxygen. The following features are standard on the MX300-I instruments:

Large easy to read 3 1/2 digit LCD display (see options)

Automatic LCD back lighting upon key press

Microprocessor controlled

Up/Down front panel controls

Sensor fail/disconnect alarm indicator (audible and visual)

Alarm silence button

2000 operating hours from 3 AA alkaline batteries

Battery status indicator

Stand for upright tabletop deployment

Hardware for pole clamping and V block support

Rugged high impact ABS construction

Splash resistant case.

Long life (36 months in air) class R17MED sensor

0-1 VDC digital output (optional RS-232)

FDA approved and cleared for CSA/CE marking

2 User defined set point controlled concentration alarms

Battery test function

1.3Options

The following instrument options are available for the MX300-I units:

A-Option—3-digit LCD display instead of 3 1/2 digit

B-Option—RS 232 digital output instead of 0-1VDC

Note: Contact the factory for retrofitting an existing instrument for 3-digit LCD display. For RS-232 reconfiguration, see

Teledyne Analytical Instruments

11

Image 11
Contents MX300-I MX300-I About This Manual How To Use This ManualSafety Messages Table of Contents Appendix MX300-I Front View List of FiguresList of Tables MX300-I Front View IntroductionIntroduction MX300-I Applicable StandardsOptions FeaturesTheory of Operation ApplicationsSensor Signal ProcessingIntroduction MX300-I Operation SetupInstalling the R17MED Sensor Sensor Installation or ReplacementSensor Cable Connection to Monitor Mounting V-Mount Adapter InstallationInstalling Batteries Battery InstallationCalibration Sequence CalibrationPortable Oxygen Monitor Operation Setting the Alarms AlarmsOutput 0-1 VDC or RS232 0-1 VDC or RS 232 Digital Output Port Use ProcedureHumidity Gas SamplingPressure TemperatureAnesthetic Gases Discrepancy in ReadingsOxygen Reading Error in a Mixture of Anesthetic Gas Do’s and Don’ts CleaningPortable Oxygen Monitor Operation Operation MX300-I Battery Maintenance General Service InformationOverall Maintenance Calibration Sensor MaintenanceAlarms Pressure Troubleshooting Troubleshooting√ Sensor Ventilate the patient, water Watchdog Error CodesOther Problems with the Instrument Return Authorization for Service Appendix SpecificationsOptional Accessories Spare Parts ListOrders should be sent to Blank Crossover IndexIndex MX300-I