Teledyne MX300-I manual Index, Crossover

Page 47

Portable Oxygen Monitor

Index

 

 

 

Index

accessories, 44 accuracy, 43 address, 42, 45 alarm

setpoints, 22 alarm

setpoints, 22 alarm setpoints, 10, 14 alarm settings

crossover of, 23

ALARM SILENCE button, 10, 14, 15 ALARM TEST button, 23, 31 amplification, 13

analog output, 23 analysis range, 10, 43 anesthetic gas, 28 anode, 13

audio alarm, 14

BATT TEST button, 15, 20 batteries, 10, 19

battery compartment, 19 battery installation, 19 battery status indicator, 10 battery test, 34 breathing circuits, 25 cable, 16

calibration, 20, 21, 34 calibration interval, 27, 36 cathode, 13

CHECK SENSOR button, 10, 12, 37 concentration alarms, 10 confined volumes, 25

copyright, ii

current output. See output diffusion sampling, 17 digital output, 24 dilution effects, 26, 35 display, 9

diverter, 13, 17, 25, 30 drift, 27, 35 electrolyte, 13 error, 28, 29

error code, 40

FCC, ii features, 11 front panel, 9

front panel MX300-I, 9 galvanic cell, 13

HI alarm, 43 defeating, 22

humidity, 26, 35 intended use warning, iv interface, 9

jumper, 24 linear, 10, 23 LO alarm, 43 LOCK/UNLOCK button, 15 maintenance, 33 moisture, 26, 35 mounting bracket, 15 nebulizer, 26, 35

nitrous oxide, 29

optional accessories. See accessories output, 12

output port, 24 oxygen sensor, 12 partial pressure, 27, 36 power, 15

power requirements, 10, 43 R17MED, 10, 12, 25, 29, 34 RAM, 14

reading discrepancy, 27, 36 reading error, 27, 28, 35 rear panel, 18 reconfiguring output, 24 resetting alarms, 10 response, 43

restriction on selling. See sale restriction

safety information, iv sale restriction, ii sensor, 10, 12 sensor cable, 43 sensor failure alarm, 10 sensor life, 43 sensor maintenance, 34

Teledyne Analytical Instruments

47

Image 47
Contents MX300-I MX300-I About This Manual How To Use This ManualSafety Messages Table of Contents Appendix MX300-I Front View List of FiguresList of Tables MX300-I Front View IntroductionIntroduction MX300-I Applicable StandardsOptions FeaturesTheory of Operation ApplicationsSensor Signal ProcessingIntroduction MX300-I Operation SetupInstalling the R17MED Sensor Sensor Installation or ReplacementSensor Cable Connection to Monitor Mounting V-Mount Adapter InstallationInstalling Batteries Battery InstallationCalibration Sequence CalibrationPortable Oxygen Monitor Operation Setting the Alarms AlarmsOutput 0-1 VDC or RS232 0-1 VDC or RS 232 Digital Output Port Use ProcedureHumidity Gas SamplingPressure TemperatureAnesthetic Gases Discrepancy in ReadingsOxygen Reading Error in a Mixture of Anesthetic Gas Do’s and Don’ts CleaningPortable Oxygen Monitor Operation Operation MX300-I Battery Maintenance General Service InformationOverall Maintenance Calibration Sensor MaintenanceAlarms Pressure Troubleshooting Troubleshooting√ Sensor Ventilate the patient, water Watchdog Error CodesOther Problems with the Instrument Return Authorization for Service Appendix SpecificationsOptional Accessories Spare Parts ListOrders should be sent to Blank Crossover IndexIndex MX300-I